Original file line number Diff line number Diff line change
Expand Up @@ -52,27 +52,40 @@
</attribute>

<doc>
Group of multiple application definitions for "multi-modal" (e.g. SAXS/WAXS) measurements.
Group to enable the combination of multiple application definitions for "multi-modal"
measurements (e.g. multi-technique methods like SAXS/WAXS).

``NXsubentry`` is a base class virtually identical to :ref:`NXentry`
and is used as the (overlay) location for application definitions.
Use a separate ``NXsubentry`` for each application definition.
Use a separate ``NXsubentry`` for each application definition.

To illustrate, consider the normal way to define a NeXus file::

NXentry
definition = name of application definition
# all the structure of the application definition
# Note, no use of NXsubentry

With NXsubentry, one can combine application definitions within a single NXentry::

To use ``NXsubentry`` with a hypothetical application definition
called ``NXmyappdef``:
NXentry
# no definition field required here
NXsubentry
definition = name of application definition
# all the structure of the application definition
NXsubentry
definition = name of a second application definition
# all the structure of the second application definition

Notes:

* Create a group with attribute ``NX_class="NXsubentry"``
* Within that group, create a field called ``definition="NXmyappdef"``.
* There are two optional attributes of definition: ``version`` and ``URL``
* Groups like NXinstrument can be included outside of NXsubentry under NXentry
allowing them to be cited in mulitple NXsubentries
* An NXsubentry should not contain another NXsubentry

The intended use is to define application definitions for a
multi-modal (a.k.a. multi-technique) :ref:`NXentry`.
Previously, an application definition
replaced :ref:`NXentry` with its own definition.
With the increasing popularity of instruments combining
multiple techniques for data collection (such as SAXS/WAXS instruments),
it was recognized the application definitions must be entered in the NeXus
data file tree as children of :ref:`NXentry`.
See rules for :ref:`NXsubentry or Multi-Method Data &lt;rules-subentry&gt;` for a
more in depth example.
</doc>

<attribute name="IDF_Version">
Expand Down
9 changes: 5 additions & 4 deletions manual/source/examples/hierarchy-subentry.txt
Original file line number Diff line number Diff line change
Expand Up @@ -12,17 +12,18 @@
SAS:NXsubentry
definition = "NXsas"
instrument:NXinstrument
detector:NXdetector
data --> /entry/instrument/SASdet/data
detector -> entry/instrument/SASdet
data:NXdata
data --> /entry/instrument/SASdet/data
sample --> /entry/sample
Fluo:NXsubentry
definition = "NXfluo"
instrument:NXinstrument
detector --> /entry/instrument/fluordet/data
detector2 --> /entry/instrument/large_area/data
detector --> /entry/instrument/fluordet
detector2 --> /entry/instrument/large_area
data:NXdata
@signal = detector
@axes = [".", "."]
detector --> /entry/instrument/fluordet/data
sample --> /entry/sample
data:NXdata --> /entry/Fluo/data