70 changes: 70 additions & 0 deletions templates/release/de/charger/pracht-alpha-duo.yaml
Original file line number Diff line number Diff line change
@@ -0,0 +1,70 @@
template: pracht-alpha
product:
identifier: pracht-alpha-duo
brand: Pracht
description: Alpha Duo
requirements: ["sponsorship"]
description: |
Eine Pracht Alpha Duo wird als zwei Pracht Alpha Mono mit unterschiedlichen `connector` Werten konfiguriert.

Eine Identifikation des Fahrzeugs über die RFID Karte ist nicht möglich.

Um Kommunikationsprobleme durch die doppelte Verbindung zu verhindern, empfiehlt es sich einen [`modbusproxy`](/docs/reference/configuration/modbusproxy) einzurichten.
Die Wallbox kommuniziert per `Modbus RTU` mit `baudrate: 9600`, `comset: "8N1"` und `id: 1`.

In der Beispielkonfiguration ist der `modbusproxy` unter `host: 127.0.0.1` und `port: 5021` erreichbar.

Verbindungen zum `modbusproxy` nutzen immer `modbus: tcpip`.

Beispiel ist für den linken Ladepunkt. Tipp: Nutze `name: pracht_links`

Füge den rechten Ladepunkt als Kopie linken hinzu und ändere `connector:` zu `2`, sowie `name` z.B. zu `pracht_rechts`.

render:
- default: |
type: template
template: pracht-alpha

# Modbus TCP zur Verbindung zu modbusproxy
modbus: tcpip
id: 1
host: 127.0.0.1 # modbusproxy
port: 5021 # modbusproxy
connector: 1 # Linker Ladepunkt
timeout: 10s # Zeitüberschreitung, optional

params:
- name: modbus
example:
default:
choice: ['tcpip']
unit:
description: Modbus Typ. tcpip für Proxy
help:
advanced: false
optional: true
- name: timeout
example: 10s
default:
choice: []
unit:
description: Zeitüberschreitung
help:
advanced: false
optional: true
- name: connector
example:
default: 1
choice: []
unit:
description: Ladepunkt (1 für den Linken Ladepunkt, 2 für den rechten Ladepunkt)
help:
advanced: true
optional: true
modbus: # Verbindung zum modbusproxy
host: 127.0.0.1 # modbusproxy
id: 1
port: 5021 # modbusproxy
rs485serial: false
rs485tcpip: false
tcpip: true
71 changes: 71 additions & 0 deletions templates/release/en/charger/pracht-alpha-duo.yaml
Original file line number Diff line number Diff line change
@@ -0,0 +1,71 @@
template: pracht-alpha
product:
identifier: pracht-alpha-duo
brand: Pracht
description: Alpha Duo
requirements: ["sponsorship"]
description: |
A Pracht Alpha Duo is configured as two Pracht Alpha Mono chargers with modified `connector` settings.

Vehicle identification via RFID is not possible.

Configure [`modbusproxy`](/docs/reference/configuration/modbusproxy) so there are no connection issues caused by using multiple connections.

The wallbox uses `Modbus RTU` with `baudrate: 9600`, `comset: "8N1"` and `id: 1`.

In the example below, the `modbusproxy` can be reached on `host: 127.0.0.1` and `port: 5021`.

Connections to `modbusproxy` must use `modbus: tcpip`.

Example configuration for the left Loadpoint. Tipp: Use `name: pracht_left`

Add the right Loadpoint as a copy of the left Loadpoint und change `connector:` to `2`, and `name` e.g. to `pracht_right`.

render:
- default: |
type: template
template: pracht-alpha

# Modbus TCP for connecting to modbusproxy
modbus: tcpip
id: 1
host: 127.0.0.1 # modbusproxy
port: 5021 # modbusproxy
connector: 1 # left Loadpoint
timeout: 10s # Timeout, optional

params:
- name: modbus
example:
default:
choice: ['tcpip']
unit:
description: Modbus Typ. tcpip for proxy
help:
advanced: false
optional: true
- name: timeout
example: 10s
default:
choice: []
unit:
description: Timeout
help:
advanced: false
optional: true
- name: connector
example:
default: 1
choice: []
unit:
description: Loadpoint (1 for the left Loadpoint, 2 for the right Loadpoint)
help:
advanced: true
optional: true
modbus: # connection to modbusproxy
host: 127.0.0.1 # modbusproxy
id: 1
port: 5021 # modbusproxy
rs485serial: false
rs485tcpip: false
tcpip: true