Skip to content
Draft
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
50 changes: 25 additions & 25 deletions hpxml-measures/BuildResidentialHPXML/README.md

Large diffs are not rendered by default.

228 changes: 28 additions & 200 deletions hpxml-measures/BuildResidentialHPXML/measure.xml

Large diffs are not rendered by default.

Original file line number Diff line number Diff line change
Expand Up @@ -30,8 +30,6 @@ None
"Propane, Standard, 100% Usage" CombinedEnergyFactor 3.3 propane conventional
"Propane, Standard, 150% Usage" CombinedEnergyFactor 3.3 propane conventional 1.5
"Propane, Standard, 200% Usage" CombinedEnergyFactor 3.3 propane conventional 2
HERS Reference: Electricity CombinedEnergyFactor 3.01 electricity conventional
HERS Reference: Natural Gas CombinedEnergyFactor 3.01 natural gas conventional
"Detailed Example: Electricity, EF 4.29" EnergyFactor 4.29 electricity condensing
"Detailed Example: Electricity, Standard, Conditioned Basement" CombinedEnergyFactor 3.73 electricity conventional basement - conditioned
"Detailed Example: Electricity, Standard, Unconditioned Basement" CombinedEnergyFactor 3.73 electricity conventional basement - unconditioned
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -25,7 +25,6 @@ None
"CEE Tier II, 2018, 100% Usage" IntegratedModifiedEnergyFactor 2.92 125 0.12 1.09 9 6 5.2
"CEE Tier II, 2018, 150% Usage" IntegratedModifiedEnergyFactor 2.92 125 0.12 1.09 9 6 5.2 1.5
"CEE Tier II, 2018, 200% Usage" IntegratedModifiedEnergyFactor 2.92 125 0.12 1.09 9 6 5.2 2
HERS Reference IntegratedModifiedEnergyFactor 1 400 0.12 1.09 27 6 3
Detailed Example: MEF 1.65 ModifiedEnergyFactor 1.65 380 0.12 1.09 27 6 3.2
"Detailed Example: Standard, 2008-2017, Conditioned Basement" IntegratedModifiedEnergyFactor 1.21 380 0.12 1.09 27 6 3.2 basement - conditioned
"Detailed Example: Standard, 2008-2017, Unconditioned Basement" IntegratedModifiedEnergyFactor 1.21 380 0.12 1.09 27 6 3.2 basement - unconditioned
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -15,7 +15,6 @@ None
"EnergyStar, Compact, 100% Usage" RatedAnnualkWh 203 0.12 1.09 14.2 4 8
"EnergyStar, Compact, 150% Usage" RatedAnnualkWh 203 0.12 1.09 14.2 4 8 1.5
"EnergyStar, Compact, 200% Usage" RatedAnnualkWh 203 0.12 1.09 14.2 4 8 2
HERS Reference RatedAnnualkWh 467 0.12 1.09 33.12 4 12
"Detailed Example: EF 0.7, Compact" EnergyFactor 0.7 0.12 1.09 22.32 4 6
"Detailed Example: Federal Minimum, Standard, Conditioned Basement" RatedAnnualkWh 307 0.12 1.09 22.32 4 12 basement - conditioned
"Detailed Example: Federal Minimum, Standard, Unconditioned Basement" RatedAnnualkWh 307 0.12 1.09 22.32 4 12 basement - unconditioned
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -33,9 +33,6 @@ None
"348 kWh/yr, 90% Usage" 348 0.9
"348 kWh/yr, 100% Usage" 348
"348 kWh/yr, 110% Usage" 348 1.1
HERS Reference: 2-Bedroom Home 673
HERS Reference: 3-Bedroom Home 691
HERS Reference: 4-Bedroom Home 709
"Detailed Example: 650 kWh/yr, Conditioned Basement" 650 basement - conditioned
"Detailed Example: 650 kWh/yr, Unconditioned Basement" 650 basement - unconditioned
"Detailed Example: 650 kWh/yr, Garage" 650 garage
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -11,8 +11,6 @@ Option Name Pipe Insulation Nominal R-Value [F-ft2-hr/Btu] System Type Standard
"Insulated, Recirc, Temperature Control" 3 Recirculation temperature
"Insulated, Recirc, Presence Sensor Demand Control" 3 Recirculation presence sensor demand control
"Insulated, Recirc, Manual Demand Control" 3 Recirculation manual demand control
"HERS Hot Water Tests: Insulated, Recirc, Uncontrolled" 3 Recirculation no control 10 50
"HERS Hot Water Tests: Insulated, Recirc, Manual Demand Control" 3 Recirculation manual demand control 10 50

# Pipe Insulation Nominal R-Value: Nominal R-value of the pipe insulation.
# System Type: The type of hot water distribution system.
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -16,7 +16,6 @@ None
"55% Efficient, Preheats Hot Only, 1 Shower" 0.55 one FALSE
"55% Efficient, Preheats Hot and Cold, All Showers" 0.55 all TRUE
"55% Efficient, Preheats Hot and Cold, 1 Shower" 0.55 one TRUE
"HERS Hot Water Tests: 54% Efficient, Preheats Hot and Cold, All Showers" 0.54 all TRUE

# Efficiency: The efficiency of the DWHR according to CSA 55.1.
# Facilities Connected: Use 'one' if there are All Showers and only one of them is connected to the DWHR. Use 'all' if there is one shower and it's connected to the DWHR or there are two or more showers connected to the DWHR.
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -42,8 +42,6 @@ Space-Heating Boiler w/ Tankless Coil space-heating boiler with tankless coil
"Detailed Example: Electricity, Heat Pump, 80 gal, EF 3.1" heat pump water heater electricity EnergyFactor 3.1 80
"Detailed Example: Natural Gas, Tank, 50 gal, EF 0.59" storage water heater natural gas EnergyFactor 0.59 50
"Detailed Example: Natural Gas, Tankless, EF 0.95" instantaneous water heater natural gas EnergyFactor 0.95
"HERS Hot Water Tests: Natural Gas, Tank, 40 gal, EF 0.56" storage water heater natural gas EnergyFactor 0.56 40 0.78
"HERS Hot Water Tests: Natural Gas, Tank, 40 gal, EF 0.62" storage water heater natural gas EnergyFactor 0.62 40 0.78

# Type: The type of water heater.
# Fuel Type: The fuel type of the water heater.
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -37,7 +37,6 @@ Very Leaky very leaky
0.67 nACH ACHnatural 0.67
1.0 nACH ACHnatural 1
1.5 nACH ACHnatural 1.5
HERS Reference SpecificLeakageArea 0.00036
Detailed Example: 3.57 ACH50 ACH 50 3.57
Detailed Example: 12.16 ACH50 ACH 50 12.16
Detailed Example: 2.8 ACH45 ACH 45 2.8
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -6,7 +6,6 @@ None 0 0
80% Carpet 0.8 2
100% Carpet 1 2
"Detailed Example: 100% Carpet, R-2.5" 1 2.5
ASHRAE 140 Tests 1 2.08

# Fraction: The fraction of floor area covered by carpet.
# R-Value: R-value for the carpet.
Original file line number Diff line number Diff line change
Expand Up @@ -11,8 +11,5 @@ IECC U-0.035 28.57
IECC U-0.030 33.33
IECC U-0.026 38.46
IECC U-0.024 41.67
ASHRAE 140 Tests: R-11 11.75
ASHRAE 140 Tests: R-19 18.45
ASHRAE 140 Tests: R-19 + R-38 57.49

# Assembly R-Value: Assembly R-value for the ceiling.
Original file line number Diff line number Diff line change
Expand Up @@ -14,6 +14,5 @@ IECC U-0.35 2.86
IECC U-0.32 3.13
IECC U-0.30 3.33
"Detailed Example: Insulated Fiberglass/Steel, R-4.4" 4.4
ASHRAE 140 Tests: Solid Wood 3.04

# R-Value: R-value of the opaque door(s).
Original file line number Diff line number Diff line change
Expand Up @@ -13,9 +13,6 @@ Option Name Type Assembly R-Value [F-ft2-hr/Btu]
"Wood Frame, IECC U-0.047" WoodFrame 21.28
"Wood Frame, IECC U-0.033" WoodFrame 30.3
"Wood Frame, IECC U-0.028" WoodFrame 35.71
"HERS DSE Tests: Wood Frame, R-11" WoodFrame 13.85
"ASHRAE 140 Tests: Wood Frame, Uninsulated" WoodFrame 2.16
"ASHRAE 140 Tests: Wood Frame, R-11" WoodFrame 12.07

# Type: The type of floor.
# Assembly R-Value: Assembly R-value for the floor excluding any carpet.
Original file line number Diff line number Diff line change
Expand Up @@ -31,7 +31,6 @@ None
"5ft, Right Windows" 5 1 4
"10ft, Right Windows" 10 1 4
"Detailed Example: 1.5ft, Back/Left/Right Windows, 2ft Offset, 4ft Window Height" 1.5 1.5 1.5 2 6
"ASHRAE 140 Tests: 2.5ft, Front Windows" 2.5 1 6

# Front Depth: The depth of overhangs for windows for the front facade.
# Back Depth: The depth of overhangs for windows for the back facade.
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -10,7 +10,5 @@ Uninsulated 2.5
"Exterior, R-10" 12.5
"Exterior, R-15" 17.5
"Exterior, R-20" 22.5
ASHRAE 140 Tests: Uninsulated 4.34
ASHRAE 140 Tests: R-11 12.47

# Assembly R-Value: Assembly R-value for the rim joist excluding any siding.
Original file line number Diff line number Diff line change
Expand Up @@ -10,7 +10,6 @@ IECC U-0.035 28.57 28.57
IECC U-0.030 33.33 33.33
IECC U-0.026 38.46 38.46
IECC U-0.024 41.67 41.67
ASHRAE 140 Tests: Uninsulated 1.99

# Unconditioned Assembly R-Value: Assembly R-value for the roof if above an unconditioned attic.
# Conditioned Assembly R-Value: Assembly R-value for the roof if above conditioned space.
Original file line number Diff line number Diff line change
Expand Up @@ -48,9 +48,6 @@ Option Name Type Color Solar Absorptance Emittance
"Concrete, Light" concrete light
"Concrete, Reflective" concrete reflective
Cool Roof cool roof reflective
ASHRAE 140 Tests: Low Solar Absorptance asphalt or fiberglass shingles 0.2 0.9
ASHRAE 140 Tests: Typical Solar Absorptance asphalt or fiberglass shingles 0.6 0.9
HERS Reference 0.75 0.9

# Type: The type of roof material.
# Color: The color of the roof.
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -48,9 +48,6 @@ Option Name Type Assembly R-Value [F-ft2-hr/Btu]
"Wood Stud, IECC U-0.057" WoodStud 17.54
"Wood Stud, IECC U-0.048" WoodStud 20.83
"Wood Stud, IECC U-0.045" WoodStud 22.22
"ASHRAE 140 Tests: Wood Stud, Uninsulated" WoodStud 4.17
"ASHRAE 140 Tests: Wood Stud, R-11" WoodStud 11.09
"ASHRAE 140 Tests: Wood Stud, R-18" WoodStud 15.71

# Type: The type of wall.
# Assembly R-Value: Assembly R-value for the wall excluding any siding and/or continuous insulation.
Original file line number Diff line number Diff line change
Expand Up @@ -10,6 +10,5 @@ R-15 15
R-18 18
R-20 20
R-21 21
ASHRAE 140 Tests: R-7.2 7.2

# R-Value: The R-value for the wall continuous insulation.
Original file line number Diff line number Diff line change
Expand Up @@ -66,9 +66,6 @@ None not present medium 0
"Masonite, Medium Light" masonite siding medium light 0.2
"Masonite, Light" masonite siding light 0.2
"Masonite, Reflective" masonite siding reflective 0.2
ASHRAE 140 Tests: Low Solar Absorptance masonite siding 0.2 0.9 0.67
ASHRAE 140 Tests: Typical Solar Absorptance masonite siding 0.6 0.9 0.67
HERS Reference 0.75 0.9 0.67

# Type: The type of wall siding.
# Color: The color of the walls.
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -43,8 +43,6 @@ Option Name U-Factor [Btu/hr-ft2-F] SHGC
"EnergyStar, Northern" 0.22 0.17
"EnergyStar, South-Central" 0.28 0.23
"EnergyStar, Southern" 0.32 0.23
"ASHRAE 140 Tests: Single, Clear" 1.039 0.67
"ASHRAE 140 Tests: Double, Low-E" 0.3 0.335

# U-Factor: Full-assembly NFRC U-factor.
# SHGC: Full-assembly NFRC solar heat gain coefficient.
Original file line number Diff line number Diff line change
Expand Up @@ -12,8 +12,6 @@ Above Apartment AboveApartment 0 0 0
"Belly and Wing, With Skirt" BellyAndWingWithSkirt 4 1 9.25
"Belly and Wing, No Skirt" BellyAndWingNoSkirt 4 1 9.25
"Detailed Example: Crawlspace, Vented, Above-Grade" VentedCrawlspace 4 4 9.25
"ASHRAE 140 Tests: Basement, Conditioned" ConditionedBasement 7.25 0.667 9
"ASHRAE 140 Tests: Basement, Unconditioned" UnconditionedBasement 7.25 0.667 9

# Type: The foundation type of the building. Garages are assumed to be over slab-on-grade.
# Height: The height of the foundation.
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -63,7 +63,6 @@ None Percent 0 0 0
"Detailed Example: 4 CFM25 per 100ft2 (75% Supply), R-4" CFM25 per 100ft2 4 4 4 0.75
"Detailed Example: 5 CFM50 per 100ft2 (75% Supply), R-4" CFM50 per 100ft2 5 4 4 0.75
"Detailed Example: 400 CFM50 (75% Supply), R-6" CFM50 400 6 6 0.75
"HERS DSE Tests: 250 CFM25, R-6" CFM25 250 6 6

# Leakage Units: The units for the duct leakage.
# Leakage to Outside Value: The leakage to outside value.
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -53,7 +53,6 @@ None none
"Detailed Example: Central HP, SEER 17.5, HSPF 9.5, Normalized Detailed Performance" air-to-air SEER 17.5 variable speed HSPF 9.5 Normalized capacity fractions "47.0, 17.0, 5.0" "0.28, 0.10, 0.03" "1.00, 0.69" "1.00, 0.69, 0.55" "4.68, 1.57, 0.47" "3.4, 2.58" "3.4, 2.58, 2.63" "95.0, 82.0" "0.33, 0.37" 1 "1.0, 1.13" "4.47, 6.33" 2.64 "2.64, 3.46"
"Detailed Example: Ductless Mini-Split HP, SEER2 19.0, HSPF2 9.0, Absolute Detailed Performance" mini-split SEER2 19 variable speed HSPF2 9 Absolute capacities "47.0, 17.0, 5.0, -13.0" "11400, 5600, 3600, 2600" "38000, 23000, 22000" "46500, 25000, 22000, 16000" "3.48, 2.78, 1.88, 1.52" "2.68, 2.2, 1.8" "2.75, 2.11, 1.8, 1.31" "95.0, 82.0" "9100, 9900" 36000 "36400, 43300" "3.76, 4.61" 2.49 "2.45, 3.51"
"Detailed Example: Ductless Mini-Split HP, SEER2 19.0, HSPF2 9.0, Normalized Detailed Performance" mini-split SEER2 19 variable speed HSPF2 9 Normalized capacity fractions "47.0, 17.0, 5.0, -13.0" "0.30, 0.15, 0.09, 0.07" "1.00, 0.61, 0.58" "1.22, 0.66, 0.58, 0.42" "3.48, 2.78, 1.88, 1.52" "2.68, 2.2, 1.8" "2.75, 2.11, 1.8, 1.31" "95.0, 82.0" "0.25, 0.28" 1 "1.01, 1.20" "3.76, 4.61" 2.49 "2.45, 3.51"
"HERS HVAC Tests: Central HP, SEER2 12.4, HSPF2 8.4" air-to-air SEER2 12.4 single stage HSPF2 8.4

# Type: The type of system.
"# Cooling Efficiency Type: The cooling efficiency type. Central HPs and Mini-Split HPs use SEER2 or SEER; Geothermal HPs, Packaged Terminal HPs, and Room HPs use EER."
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -45,7 +45,6 @@ None
"100% CFL, 100% Usage" 1 0 0 1 0 0 1 0 0
"100% CFL, 150% Usage" 1 0 0 1.5 1 0 0 1.5 1 0 0 1.5
"100% CFL, 200% Usage" 1 0 0 2 1 0 0 2 1 0 0 2
HERS Reference 0.1 0 0 0 0 0 0 0 0
"Detailed Example: 40% CFL, 10% LFL, 25% LED" 0.4 0.1 0.25 0.4 0.1 0.25 0.4 0.1 0.25

"# Interior Fraction CFL: Fraction of all interior lamps that are compact fluorescent. Lighting not specified as CFL, LFL, or LED is assumed to be incandescent."
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -14,7 +14,6 @@ None 0
300% Usage 3
400% Usage 4
Detailed Example: 2457 kWh/yr 2457 0.855 0.045
ASHRAE 140 Tests 7302 0.822 0.178

# Annual Energy Use: The annual energy consumption of the plug loads.
"# Usage Multiplier: Multiplier on the energy usage that can reflect, e.g., high/low usage occupants."
Expand Down
Loading