Skip to content

kube-metrics-adapter (with pod collector enabled) returns stale data  #97

@rahanar

Description

@rahanar

Hello,

I have been testing kube-metrics-adapter (with pod collector enabled) and noticed that it returns stale data during specific conditions, which results in HPA misbehaving. The conditions occur when HPA scales up a deployment due to high load, then load subsides and it scales the deployment back to min-replica. However, if I increase the load again that should result in a scale-up, the HPA would not scale up because the data it is acting upon is stale. When it queries kube-metrics-adapter for custom metrics, the adapter is returning old data that contains non-existent pods and old values. This results in incorrect averages for the HPA.

I tracked it down to the in-memory cache that kube-metrics-adapter uses to track pods and metrics. The metrics have TTL of 15 mins and the GC is run every 10 mins. The issue mentioned above disappears after old metrics are cleaned up by GC. To fix the issue permanently, I modified TTL to 30s and GC to run every minute. HPA is able to act on new conditions much better. This should cover other edge cases, such as if HPA is in a middle of scale-down and there is a new load, it should able to act on it faster.

I think this is a simple solution for now that solves the issue and there is a better way of dealing with it. The cache can be updated on each run, so HPA can have an up-to-date view of the cluster without a delay of up to 1 minute.

Expected Behavior

kube-metrics-adapter doesn't return stale data to HPA that contains information about non-existent pods and their values.

Actual Behavior

kube-metrics-adapter returns stale data to HPA due to 15min TTL and 10 mins garbage collection. This causes HPA to calculate wrong averages based on custom metrics.

Steps to Reproduce the Problem

  1. Let HPA scale up a deployment based on a custom metric from pod (pod collector)
  2. Let HPA scale down the deployment due to load subsiding
  3. As soon as the deployment hits minReplica, increase the load. Notice that averages in HPA are not correct. Specifically, the average is a function of the current value of the custom metric divided by number of pods that HPA scaled up to previously.

Specifications

  • Version: v0.0.5

I have a fix for this, but would like to discuss if it is appropriate. I propose to make TTL and GC run configurable and set the default values to 30s and 1m respectively. A better long term solution can be keeping the the cache up-to-date on each run.