318 changes: 318 additions & 0 deletions Eaton/Eaton__9E2000i__usbhid-ups__2.8.4.787-787+gf8ecd520a__01.dev
Original file line number Diff line number Diff line change
@@ -0,0 +1,318 @@
# DEVICE:COMMENT:
# Device dump generated by ./nut-ddl-dump.sh on Wed, 26 Nov 2025 21:26:38 +0200
# DEVICE:EOC

# :; upsc [email protected]
battery.capacity: 7.00
battery.charge: 100
battery.charge.low: 20
battery.charge.restart: 0
battery.charger.type: Constant Charge (CC)
battery.protection: yes
battery.runtime: 3353
battery.runtime.low: 180
battery.type: PbAc
battery.voltage: 83.0
battery.voltage.nominal: 72
device.mfr: EATON
device.model: 9E2000i
device.serial: GE16F43216
device.type: ups
device.usb.version: 01.29
driver.debug: 0
driver.flag.allow_killpower: 0
driver.name: usbhid-ups
driver.parameter.interrupt_pipe_no_events_tolerance: -1
driver.parameter.pollfreq: 30
driver.parameter.pollinterval: 2
driver.parameter.port: auto
driver.parameter.synchronous: auto
driver.state: quiet
driver.version: 2.8.4.787-787+gf8ecd520a
driver.version.data: MGE HID 1.57
driver.version.internal: 0.71
driver.version.usb: libusb-1.0.29 (API: 0x0100010A)
experimental.ups.mode.buzzwords: vendor:mge-hid:ECO vendor:default:ECO
input.bypass.frequency: 49.9
input.bypass.switch.off: disabled
input.bypass.switch.on: disabled
input.bypass.switchable: enabled
input.bypass.voltage: 235.0
input.eco.switchable: ECO
input.frequency: 49.9
input.frequency.nominal: 50
input.transfer.bypass.forced: enabled
input.transfer.bypass.high: 264
input.transfer.bypass.low: 184
input.transfer.bypass.overload: enabled
input.transfer.eco.high: 243
input.transfer.eco.low: 218
input.transfer.frequency.bypass.range: 10
input.transfer.frequency.eco.range: 5
input.transfer.high: 300
input.transfer.hysteresis: 10
input.transfer.low: 100
input.voltage: 235.0
input.voltage.nominal: 235
outlet.1.designator: AC OUTPUT
outlet.1.protect.status: protected
outlet.1.status: on
outlet.desc: Main Outlet
outlet.id: 0
outlet.switchable: no
output.current: 1.40
output.frequency: 49.9
output.frequency.nominal: 50
output.voltage: 236.0
output.voltage.nominal: 230
ups.beeper.status: enabled
ups.delay.shutdown: 20
ups.delay.start: 30
ups.firmware: 00.02.000
ups.load: 17
ups.load.high: 105
ups.mfr: EATON
ups.model: 9E2000i
ups.power: 340
ups.power.nominal: 2000
ups.productid: ffff
ups.realpower: 296
ups.realpower.nominal: 1600
ups.serial: GE16F43216
ups.shutdown: enabled
ups.start.auto: yes
ups.start.battery: yes
ups.start.reboot: yes
ups.status: OL
ups.temperature: 24.9
ups.test.interval: 604800
ups.test.result: Done and passed
ups.timer.shutdown: -1
ups.timer.start: -1
ups.type: online
ups.vendorid: 0463

# DEVICE:COMMENT-BLOCK:FIXME:UPSRW: [email protected]
# [battery.charge.low]
# Remaining battery level when UPS switches to LB (percent)
# Type: STRING
# Maximum length: 5
# Value: 20
#
# [battery.charge.restart]
# Minimum battery level for restart after power off (percent)
# Type: STRING
# Maximum length: 3
# Value: 0
#
# [battery.protection]
# Prevent deep discharge of battery
# Type: STRING
# Maximum length: 5
# Value: yes
#
# [battery.runtime.low]
# Remaining battery runtime when UPS switches to LB (seconds)
# Type: STRING
# Maximum length: 10
# Value: 180
#
# [driver.debug]
# Current debug verbosity level of the driver program
# Type: NUMBER
# Value: 0
#
# [driver.flag.allow_killpower]
# Safety flip-switch to allow the driver daemon to send UPS shutdown command (accessible via driver.killpower)
# Type: NUMBER
# Value: 0
#
# [input.bypass.switch.off]
# Take the UPS out of Bypass mode
# Type: STRING
# Maximum length: 12
# Value: disabled
#
# [input.bypass.switch.on]
# Put the UPS in Bypass mode
# Type: STRING
# Maximum length: 8
# Value: disabled
#
# [input.bypass.switchable]
# Input auto transfer on Bypass when overload or out of tolerance (enabled or disabled)
# Type: STRING
# Maximum length: 8
# Value: enabled
#
# [input.eco.switchable]
# Input High Efficiency (aka ECO) mode switch
# Type: STRING
# Maximum length: 8
# Value: ECO
#
# [input.transfer.bypass.forced]
# Rule for allow auto Bypass switch (on/off) transfer modes (enabled or disabled)
# Type: STRING
# Maximum length: 8
# Value: enabled
#
# [input.transfer.bypass.high]
# High voltage Bypass transfer point (V)
# Type: STRING
# Maximum length: 5
# Value: 264
#
# [input.transfer.bypass.low]
# Low voltage Bypass transfer point (V)
# Type: STRING
# Maximum length: 5
# Value: 184
#
# [input.transfer.bypass.overload]
# Rule for auto transfer on Bypass when overload (enabled or disabled)
# Type: STRING
# Maximum length: 8
# Value: enabled
#
# [input.transfer.eco.high]
# High voltage ECO transfer point (V)
# Type: STRING
# Maximum length: 5
# Value: 243
#
# [input.transfer.eco.low]
# Low voltage ECO transfer point (V)
# Type: STRING
# Maximum length: 5
# Value: 218
#
# [input.transfer.frequency.bypass.range]
# Frequency range Bypass transfer point (percent of nominal Hz)
# Type: STRING
# Maximum length: 5
# Value: 10
#
# [input.transfer.frequency.eco.range]
# Frequency range ECO transfer point (percent of nominal Hz)
# Type: STRING
# Maximum length: 5
# Value: 5
#
# [input.transfer.high]
# High voltage transfer point (V)
# Type: STRING
# Maximum length: 5
# Value: 300
#
# [input.transfer.hysteresis]
# Threshold of switching protection modes, voltage transfer point (V)
# Type: STRING
# Maximum length: 5
# Value: 10
#
# [input.transfer.low]
# Low voltage transfer point (V)
# Type: STRING
# Maximum length: 5
# Value: 100
#
# [outlet.desc]
# Outlet description
# Type: STRING
# Maximum length: 20
# Value: Main Outlet
#
# [output.voltage.nominal]
# Nominal output voltage (V)
# Type: ENUM STRING
# Maximum length: 3
# Option: "200"
# Option: "208"
# Option: "220"
# Option: "230" SELECTED
# Option: "240"
#
# [ups.delay.shutdown]
# Interval to wait after shutdown with delay command (seconds)
# Type: STRING
# Maximum length: 10
# Value: 20
#
# [ups.delay.start]
# Interval to wait before (re)starting the load (seconds)
# Type: STRING
# Maximum length: 10
# Value: 30
#
# [ups.load.high]
# Load when UPS switches to overload condition (percent)
# Type: STRING
# Maximum length: 5
# Value: 105
#
# [ups.shutdown]
# Enable or disable UPS shutdown ability (poweroff)
# Type: ENUM STRING
# Maximum length: 10
# Option: "disabled"
# Option: "enabled" SELECTED
#
# [ups.start.auto]
# UPS starts when mains is (re)applied
# Type: STRING
# Maximum length: 5
# Value: yes
#
# [ups.start.battery]
# Allow to start UPS from battery
# Type: STRING
# Maximum length: 5
# Value: yes
#
# [ups.start.reboot]
# UPS reboots when power returns during shutdown delay
# Type: STRING
# Maximum length: 5
# Value: yes
#
# [ups.test.interval]
# Interval between self tests (seconds)
# Type: STRING
# Maximum length: 8
# Value: 604800
# DEVICE:EOC

# DEVICE:COMMENT-BLOCK:FIXME:UPSCMD: [email protected]
# Instant commands supported on UPS [Eaton9E2000i]:
#
# beeper.disable - Disable the UPS beeper
# beeper.enable - Enable the UPS beeper
# beeper.mute - Temporarily mute the UPS beeper
# beeper.off - Obsolete (use beeper.disable or beeper.mute)
# beeper.on - Obsolete (use beeper.enable)
# bypass.start - Put the UPS in Bypass mode
# bypass.stop - Take the UPS out of Bypass mode
# driver.killpower - Tell the driver daemon to initiate UPS shutdown; should be unlocked with driver.flag.allow_killpower option or variable setting
# driver.reload - Reload running driver configuration from the file system (only works for changes in some options)
# driver.reload-or-error - Reload running driver configuration from the file system (only works for changes in some options); return an error if something changed and could not be applied live (so the caller can restart it with new options)
# driver.reload-or-exit - Reload running driver configuration from the file system (only works for changes in some options); exit the running driver if something changed and could not be applied live (so service management framework can restart it with new options)
# experimental.bypass.ecomode.start - Put UPS in Bypass mode then High Efficiency (aka ECO) mode
# experimental.bypass.ecomode.stop - Take the UPS out of High Efficiency (aka ECO) mode after exiting Bypass mode
# experimental.ecomode.start - Put UPS in High Efficiency (aka ECO) mode
# experimental.ecomode.stop - Take the UPS out of High Efficiency (aka ECO) mode
# experimental.essmode.start - Put UPS in Energy Saver System (aka ESS) mode
# experimental.essmode.stop - Take the UPS out of Energy Saver System (aka ESS) mode
# load.off - Turn off the load immediately
# load.off.delay - Turn off the load with a delay (seconds)
# load.on - Turn on the load immediately
# load.on.delay - Turn on the load with a delay (seconds)
# shutdown.default - Run the driver-defined UPS shutdown sequence (as opposed to user-configured 'sdcommands')
# shutdown.return - Turn off the load and return when power is back
# shutdown.stayoff - Turn off the load and remain off
# shutdown.stop - Stop a shutdown in progress
# test.battery.start.deep - Start a deep battery test
# test.battery.start.quick - Start a quick battery test
# test.battery.stop - Stop the battery test
# DEVICE:EOC