@krzysztof9nowak commented
- Input fuse F1 might be unnecessary. MPPT current of a solar panel is about 90% of short circuit current, so it's impossible to select a fuse, which would fail on short circuit. However, I would consider adding some over-voltage protection in form of either Zener diodes or varistors, which could protect from voltage spikes induced by lightning strikes.
What do you think about this TVS? https://jlcpcb.com/partdetail/Brightking_Elec_taiwan-50SMDJ120CA/C729864 I see it's 26A peak amps. I'm not finding much for a better option at JLCPCB. I'd like more like 50A peak, so it has a chance of blowing the fuse if there is a surge event.
@krzysztof9nowak commented