-
Notifications
You must be signed in to change notification settings - Fork 2
Expand file tree
/
Copy pathfactory-form.html
More file actions
459 lines (377 loc) · 14.8 KB
/
factory-form.html
File metadata and controls
459 lines (377 loc) · 14.8 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
<!DOCTYPE html>
<html>
<head>
<meta charset="UTF-8">
<title>Krake Testing Register</title>
<link rel="stylesheet" href="style.css">
</head>
<body>
<h1>Krake Testing Register</h1>
<nav class="top-nav">
<a href="factory-form.html" class="nav-btn active" aria-current="page">Krake Testing Register</a>
<a href="records.html" class="nav-btn">Inventory</a>
<a href="board.html" class="nav-btn">Board Record</a>
<!-- <a href="all-tables.html" class="nav-btn">Data Base</a> -->
</nav>
<form id="test-form">
<!-- BOARD INFO -->
<fieldset>
<legend>Board Information</legend>
<label>Serial Number:
<input type="text" id="serial_number" required>
</label><br>
<label>Hardware Rev:
<input type="text" id="hardware_rev" value="Rev2.0">
</label><br>
<label>PCB Rev:
<input type="text" id="pcb_rev" value="PCB v2.0">
</label><br>
<label>Batch:
<input type="text" id="batch" placeholder="e.g. 2025-03-JLC-A">
</label><br>
<label>Country:
<select id="country">
<option>Lebanon</option>
<option>UK</option>
<option>US</option>
</select>
</label><br>
<label>Lab:
<input type="text" id="lab" placeholder="Beirut Lab / London Lab / US Lab">
</label><br>
<label>Date Assembled:
<input type="date" id="date_assembled">
</label><br>
<label>Assembled By:
<input type="text" id="assembled_by">
</label><br>
<label>GDT Storage Key:
<input type="text" id="gdt_key_display" readonly>
</label><br>
<label>GDT Public URL:
<input type="text" id="gdt_url_display" readonly>
</label><br>
<label>GDT Image:
<input type="file" id="gdt_file" accept="image/*">
</label>
<small>(Optional) Upload drawing/photo for this board. Stored in Supabase Storage.</small>
<br>
</fieldset>
<br>
<!-- TEST RUN INFO -->
<fieldset>
<legend>Test Run (General)</legend>
<label>Test Location:
<select id="test_location">
<option>Lebanon</option>
<option>London</option>
<option>US</option>
</select>
</label><br>
<label>Tester:
<input type="text" id="tester" required>
</label><br>
<label>Firmware Version:
<input type="text" id="firmware_version" value="0.40">
</label><br>
<label>Test Fixture Version:
<input type="text" id="test_fixture_version" placeholder="e.g. Jig v1.0">
</label><br>
<label>Overall Result:
<select id="overall_result">
<option>PASS</option>
<option>FAIL</option>
<option>REWORK</option>
</select>
</label><br>
<label>Comments:<br>
<textarea id="comments" rows="3" cols="40"></textarea>
</label><br>
</fieldset>
<br>
<!-- UNPOWERED RESULTS -->
<fieldset>
<legend>Unpowered Test (Resistance)</legend>
<p>Test with multimeter before applying power.</p>
<label>Meter Make:
<input type="text" id="meter_make" placeholder="ASTRO AI">
</label><br>
<label>Meter Model:
<input type="text" id="meter_model" placeholder="DM6000AR">
</label><br>
<label>Meter Serial Number:
<input type="text" id="meter_sn" placeholder="2327610969">
</label><br><br>
<label>Resistance TP102–TP101 (Vin):
<input type="text" id="res_tp102_tp101_vin" placeholder=">10Meg">
</label><br>
<label>Resistance TP103–TP101 (+5V):
<input type="text" id="res_tp103_tp101_5v" placeholder="1.1K Typical">
</label><br>
<label>Resistance TP201–TP101 (VBus):
<input type="text" id="res_tp201_tp101_vbus" placeholder="Open">
</label><br>
<label>Resistance TP202–TP101 (V3):
<input type="text" id="res_tp202_tp101_v3" placeholder="304 Ohm">
</label><br>
<label>Resistance J103 Pin2–TP101 (ControllerVcc):
<input type="text" id="res_j103pin2_tp101_ctrl_vcc" placeholder=">10Meg">
</label><br>
<label>Unpowered Test Result:
<select id="unpowered_pass_fail">
<option>PASS</option>
<option>FAIL</option>
</select>
</label><br>
<label>Unpowered Notes:<br>
<textarea id="unpowered_notes" rows="2" cols="40"></textarea>
</label><br>
</fieldset>
<br>
<!-- POWERED RESULTS -->
<fieldset>
<legend>Powered Tests (Current & Voltages)</legend>
<label>Supply Current at J101 (mA):
<input type="number" step="0.1" id="supply_current_ma" placeholder="e.g. 147">
</label><br>
<label>TP102 Vin (V):
<input type="number" step="0.01" id="vin_tp102_v" placeholder="8.33">
</label><br>
<label>TP103 +5V (V):
<input type="number" step="0.01" id="v5_tp103_v" placeholder="5.046">
</label><br>
<label>+5esp32 into U103 (V):
<input type="number" step="0.01" id="v5_esp32_u103_v" placeholder="4.929">
</label><br>
<label>+3.3V Tab U103 (V):
<input type="number" step="0.01" id="v3p3_tab_u103_v" placeholder="3.318">
</label><br>
<label>TP202 V3 on U501 (V):
<input type="number" step="0.01" id="v3_tp202_u501_v" placeholder="3.314">
</label><br>
<label>D103 Cathode 3v3Controller (V):
<input type="number" step="0.01" id="v3v3_ctrl_d103k_v" placeholder="3.208">
</label><br>
<label>TP401 VccLCD (V):
<input type="number" step="0.01" id="vcclcd_tp401_v" placeholder="4.999">
</label><br>
<label>C505+ 5VDFP (V):
<input type="number" step="0.01" id="v5_dfp_c505_v" placeholder="5.031">
</label><br>
<label>ChargePump + (U701 Pin2) (V):
<input type="number" step="0.01" id="v_charge_pump_plus_v" placeholder="5.36">
</label><br>
<label>ChargePump - (U701 Pin6) (V):
<input type="number" step="0.01" id="v_charge_pump_minus_v" placeholder="-5.70">
</label><br>
<label>Powered Test Result:
<select id="powered_pass_fail">
<option>PASS</option>
<option>FAIL</option>
</select>
</label><br>
<label>Powered Notes:<br>
<textarea id="powered_notes" rows="2" cols="40"></textarea>
</label><br>
</fieldset>
<br>
<button type="submit">Save Test Run</button>
</form>
<p id="status"></p>
<!-- Supabase JS client via CDN -->
<script src="https://unpkg.com/@supabase/supabase-js@2"></script>
<script>
const SUPABASE_URL = 'https://bkonmvhzzlbrbtnvlfcr.supabase.co'
const SUPABASE_ANON_KEY = 'eyJhbGciOiJIUzI1NiIsInR5cCI6IkpXVCJ9.eyJpc3MiOiJzdXBhYmFzZSIsInJlZiI6ImJrb25tdmh6emxicmJ0bnZsZmNyIiwicm9sZSI6ImFub24iLCJpYXQiOjE3NjMyMjUxNjIsImV4cCI6MjA3ODgwMTE2Mn0.yrg1t-aHWuwVEVcUVJ4-sbz1BNSspc7c5tBSQ3APTAg'
const { createClient } = supabase
const db = createClient(SUPABASE_URL, SUPABASE_ANON_KEY)
const form = document.getElementById('test-form')
const statusEl = document.getElementById('status')
function numOrNull(id) {
const v = document.getElementById(id).value.trim()
if (v === '') return null
const n = Number(v)
return Number.isNaN(n) ? null : n
}
form.addEventListener('submit', async (e) => {
e.preventDefault()
statusEl.textContent = 'Saving...'
// --- BOARD FIELDS ---
const serial_number = document.getElementById('serial_number').value.trim()
const hardware_rev = document.getElementById('hardware_rev').value.trim()
const pcb_rev = document.getElementById('pcb_rev').value.trim()
const batch = document.getElementById('batch').value.trim()
const country = document.getElementById('country').value
const lab = document.getElementById('lab').value.trim()
const date_assembled = document.getElementById('date_assembled').value || null
const assembled_by = document.getElementById('assembled_by').value.trim()
// --- GDT FILE UPLOAD (optional) ---
const gdtFileInput = document.getElementById('gdt_file')
const file = gdtFileInput.files[0]
let gdt_key = null
let gdt_url = null
const gdtKeyEl = document.getElementById('gdt_key_display')
const gdtUrlEl = document.getElementById('gdt_url_display')
if (file) {
try {
gdt_key = `${serial_number || 'unknown'}/gdt-${Date.now()}-${file.name}`
// Upload to Storage bucket "gdt-images"
const { data: uploadData, error: uploadError } = await db.storage
.from('gdt-images')
.upload(gdt_key, file)
if (uploadError) {
console.error(uploadError)
statusEl.textContent = 'Error uploading GDT image: ' + uploadError.message
return
}
// Get public URL
const { data: publicData } = db.storage
.from('gdt-images')
.getPublicUrl(gdt_key)
gdt_url = publicData.publicUrl
// Show in UI
if (gdtKeyEl) gdtKeyEl.value = gdt_key || ''
if (gdtUrlEl) gdtUrlEl.value = gdt_url || ''
} catch (err) {
console.error(err)
statusEl.textContent = 'Unexpected error uploading GDT image: ' + err.message
return
}
} else {
// No file selected: clear any previous values
if (gdtKeyEl) gdtKeyEl.value = ''
if (gdtUrlEl) gdtUrlEl.value = ''
}
// --- TEST RUN FIELDS ---
const test_location = document.getElementById('test_location').value
const tester = document.getElementById('tester').value.trim()
const firmware_version = document.getElementById('firmware_version').value.trim()
const test_fixture_version = document.getElementById('test_fixture_version').value.trim()
const overall_result = document.getElementById('overall_result').value
const comments = document.getElementById('comments').value.trim()
// --- UNPOWERED FIELDS ---
const meter_make = document.getElementById('meter_make').value.trim()
const meter_model = document.getElementById('meter_model').value.trim()
const meter_sn = document.getElementById('meter_sn').value.trim()
const res_tp102_tp101_vin = document.getElementById('res_tp102_tp101_vin').value.trim()
const res_tp103_tp101_5v = document.getElementById('res_tp103_tp101_5v').value.trim()
const res_tp201_tp101_vbus = document.getElementById('res_tp201_tp101_vbus').value.trim()
const res_tp202_tp101_v3 = document.getElementById('res_tp202_tp101_v3').value.trim()
const res_j103pin2_tp101_ctrl_vcc = document.getElementById('res_j103pin2_tp101_ctrl_vcc').value.trim()
const unpowered_pass_fail = document.getElementById('unpowered_pass_fail').value
const unpowered_notes = document.getElementById('unpowered_notes').value.trim()
// --- POWERED FIELDS ---
const supply_current_ma = numOrNull('supply_current_ma')
const vin_tp102_v = numOrNull('vin_tp102_v')
const v5_tp103_v = numOrNull('v5_tp103_v')
const v5_esp32_u103_v = numOrNull('v5_esp32_u103_v')
const v3p3_tab_u103_v = numOrNull('v3p3_tab_u103_v')
const v3_tp202_u501_v = numOrNull('v3_tp202_u501_v')
const v3v3_ctrl_d103k_v = numOrNull('v3v3_ctrl_d103k_v')
const vcclcd_tp401_v = numOrNull('vcclcd_tp401_v')
const v5_dfp_c505_v = numOrNull('v5_dfp_c505_v')
const v_charge_pump_plus_v = numOrNull('v_charge_pump_plus_v')
const v_charge_pump_minus_v = numOrNull('v_charge_pump_minus_v')
const powered_pass_fail = document.getElementById('powered_pass_fail').value
const powered_notes = document.getElementById('powered_notes').value.trim()
try {
// 1) UPSERT BOARD
const { data: board, error: boardError } = await db
.from('boards')
.upsert({
serial_number,
hardware_rev,
pcb_rev,
batch,
country,
lab,
date_assembled,
assembled_by,
gdt_key,
gdt_url
})
.select()
.single()
if (boardError) {
console.error(boardError)
statusEl.textContent = 'Error saving board: ' + boardError.message
return
}
// 2) INSERT TEST RUN
const { data: testRun, error: runError } = await db
.from('test_runs')
.insert({
board_id: board.board_id,
tester,
firmware_version,
test_fixture_version,
test_location,
overall_result,
comments
})
.select()
.single()
if (runError) {
console.error(runError)
statusEl.textContent = 'Error saving test run: ' + runError.message
return
}
const testrun_id = testRun.testrun_id
// 3) INSERT UNPOWERED RESULTS
const { error: unpoweredError } = await db
.from('unpowered_results')
.insert({
testrun_id,
meter_make,
meter_model,
meter_sn,
res_tp102_tp101_vin,
res_tp103_tp101_5v,
res_tp201_tp101_vbus,
res_tp202_tp101_v3,
res_j103pin2_tp101_ctrl_vcc,
pass_fail: unpowered_pass_fail,
notes: unpowered_notes
})
if (unpoweredError) {
console.error(unpoweredError)
statusEl.textContent = 'Error saving unpowered results: ' + unpoweredError.message
return
}
// 4) INSERT POWERED RESULTS
const { error: poweredError } = await db
.from('powered_results')
.insert({
testrun_id,
supply_current_ma,
vin_tp102_v,
v5_tp103_v,
v5_esp32_u103_v,
v3p3_tab_u103_v,
v3_tp202_u501_v,
v3v3_ctrl_d103k_v,
vcclcd_tp401_v,
v5_dfp_c505_v,
v_charge_pump_plus_v,
v_charge_pump_minus_v,
pass_fail: powered_pass_fail,
notes: powered_notes
})
if (poweredError) {
console.error(poweredError)
statusEl.textContent = 'Error saving powered results: ' + poweredError.message
return
}
statusEl.textContent = '✅ All data saved!'
form.reset()
// Clear GDT display fields after reset
if (gdtKeyEl) gdtKeyEl.value = ''
if (gdtUrlEl) gdtUrlEl.value = ''
} catch (err) {
console.error(err)
statusEl.textContent = 'Unexpected error: ' + err.message
}
})
</script>
</body>
</html>