@@ -5,6 +5,9 @@ __New Features__
- Dual-fuel heat pumps with switchover temperatures > 25F are now autosized based on 25F to allow some additional heating capacity buffer.
- Improves handling of duct leakage specified using cfm25/cfm50.
- Crankcase heating energy is now disabled during unavailable periods, e.g., power outages.
+- Water heater updates:
+ - Allows modeling 120V HPWHs (including dedicated vs shared circuits) using `WaterHeatingSystem/HPWHVoltage`.
+ - Allows modeling water heaters with a mixing valve using `HasMixingValve` and `MixingValveSetpoint`.
- Allows "other" for `SoilType`; adds variation to dry/wet soil conductivity and diffusivity values for unknown/other/loam soil types.
- Output updates:
- **Breaking change**: Annual peak load outputs for heating and cooling now use units of Btu/h instead of kBtu/h for consistency with other outputs.
diff --git a/HPXMLtoOpenStudio/measure.xml b/HPXMLtoOpenStudio/measure.xml
index bc00afc94d..cc65a45947 100644
--- a/HPXMLtoOpenStudio/measure.xml
+++ b/HPXMLtoOpenStudio/measure.xml
@@ -3,8 +3,8 @@
3.1
hpxml_to_openstudio
b1543b30-9465-45ff-ba04-1d1f85e763bc
- 8b05dfcf-bf6e-4880-8280-e89fa9ac1f1d
- 2026-04-24T15:17:55Z
+ e3879ee8-dd46-4587-bf50-45f7b0eb092f
+ 2026-04-27T16:06:36Z
D8922A73
HPXMLToOpenStudio
HPXML to OpenStudio Translator
@@ -367,7 +367,7 @@
defaults.rb
rb
resource
- F91B9101
+ 93CB275C
electric_panel.rb
@@ -397,13 +397,13 @@
hotwater_appliances.rb
rb
resource
- 5F185DC6
+ 82516F0C
hpxml.rb
rb
resource
- BF5902DA
+ 3C44E95B
hpxml_schema/HPXML.xsd
@@ -421,7 +421,7 @@
hpxml_schematron/EPvalidator.sch
sch
resource
- 9B5934A8
+ B163569D
hpxml_schematron/iso-schematron.xsd
@@ -715,7 +715,7 @@
waterheater.rb
rb
resource
- 245FEA65
+ 08232D17
weather.rb
@@ -751,13 +751,13 @@
test_defaults.rb
rb
test
- 191743A2
+ C8BD974C
test_electric_panel.rb
rb
test
- 8E69A0EB
+ 374CB236
test_enclosure.rb
@@ -775,7 +775,7 @@
test_hotwater_appliance.rb
rb
test
- 6DBBC0A9
+ 0A4D986F
test_hvac.rb
@@ -829,7 +829,7 @@
test_validation.rb
rb
test
- FD24774E
+ 3A631903
test_vehicle.rb
@@ -841,7 +841,7 @@
test_water_heater.rb
rb
test
- 8DBA3BD3
+ 61A61CD2
test_weather.rb
diff --git a/HPXMLtoOpenStudio/resources/defaults.rb b/HPXMLtoOpenStudio/resources/defaults.rb
index f61654e997..f418a84427 100644
--- a/HPXMLtoOpenStudio/resources/defaults.rb
+++ b/HPXMLtoOpenStudio/resources/defaults.rb
@@ -3358,15 +3358,31 @@ def self.apply_water_heaters(hpxml_bldg, eri_version, schedules_file)
end
elsif water_heating_system.water_heater_type == HPXML::WaterHeaterTypeHeatPump
+
+ if water_heating_system.hpwh_voltage.nil?
+ water_heating_system.hpwh_voltage = HPXML::HPWHVoltage240
+ water_heating_system.hpwh_voltage_isdefaulted = true
+ end
+
water_heating_system.additional_properties.cop = get_water_heater_heat_pump_cop(water_heating_system)
if water_heating_system.heating_capacity.nil?
- water_heating_system.heating_capacity = (UnitConversions.convert(0.5, 'kW', 'Btu/hr') * water_heating_system.additional_properties.cop).round
+ if water_heating_system.hpwh_voltage == HPXML::HPWHVoltage240
+ water_heating_system.heating_capacity = (UnitConversions.convert(0.5, 'kW', 'Btu/hr') * water_heating_system.additional_properties.cop).round
+ elsif water_heating_system.hpwh_voltage == HPXML::HPWHVoltage120Dedicated
+ water_heating_system.heating_capacity = (UnitConversions.convert(0.422, 'kW', 'Btu/hr') * water_heating_system.additional_properties.cop).round
+ else # 120V shared
+ water_heating_system.heating_capacity = (UnitConversions.convert(0.357, 'kW', 'Btu/hr') * water_heating_system.additional_properties.cop).round
+ end
water_heating_system.heating_capacity_isdefaulted = true
end
if water_heating_system.backup_heating_capacity.nil?
- water_heating_system.backup_heating_capacity = UnitConversions.convert(4.5, 'kW', 'Btu/hr').round
+ if water_heating_system.hpwh_voltage == HPXML::HPWHVoltage240
+ water_heating_system.backup_heating_capacity = UnitConversions.convert(4.5, 'kW', 'Btu/hr').round
+ else
+ water_heating_system.backup_heating_capacity = 0.0 # No backup elements
+ end
water_heating_system.backup_heating_capacity_isdefaulted = true
end
@@ -3387,6 +3403,22 @@ def self.apply_water_heaters(hpxml_bldg, eri_version, schedules_file)
end
end
+
+ if water_heating_system.has_mixing_valve.nil?
+ if water_heating_system.water_heater_type == HPXML::WaterHeaterTypeHeatPump && water_heating_system.hpwh_voltage != HPXML::HPWHVoltage240
+ # 120V HPWH
+ water_heating_system.has_mixing_valve = true
+ else
+ water_heating_system.has_mixing_valve = false
+ end
+ water_heating_system.has_mixing_valve_isdefaulted = true
+ end
+
+ if water_heating_system.has_mixing_valve && water_heating_system.mixing_valve_setpoint.nil?
+ water_heating_system.mixing_valve_setpoint = [125.0, water_heating_system.temperature].min
+ water_heating_system.mixing_valve_setpoint_isdefaulted = true
+ end
+
next unless water_heating_system.location.nil?
iecc_zone = hpxml_bldg.climate_and_risk_zones.climate_zone_ieccs.empty? ? nil : hpxml_bldg.climate_and_risk_zones.climate_zone_ieccs[0].zone
@@ -6120,6 +6152,7 @@ def self.get_water_heater_location(hpxml_bldg, iecc_zone = nil)
# @param eri_version [String] Version of the ANSI/RESNET/ICC 301 Standard to use for equations/assumptions
# @return [Double] Water heater setpoint temperature (F)
def self.get_water_heater_temperature(eri_version)
+ # FIXME: Should we default to a different value for 120V HPWHs?
if Constants::ERIVersions.index(eri_version) >= Constants::ERIVersions.index('2014A')
# 2014 w/ Addendum A or newer
return 125.0
@@ -6268,22 +6301,28 @@ def self.get_water_heater_tank_volume(fuel, is_hpwh, nbeds, nbaths, n_occ)
# @param water_heating_system [HPXML::WaterHeatingSystem] The HPXML water heating system of interest
# @return [Double] COP of the heat pump (W/W)
def self.get_water_heater_heat_pump_cop(water_heating_system)
- # Based on simulations of the UEF test procedure at varying COPs
- if not water_heating_system.energy_factor.nil?
- uef = (0.60522 + water_heating_system.energy_factor) / 1.2101
- cop = 1.174536058 * uef
- elsif not water_heating_system.uniform_energy_factor.nil?
- uef = water_heating_system.uniform_energy_factor
- case water_heating_system.usage_bin
- when HPXML::WaterHeaterUsageBinVerySmall
- fail 'It is unlikely that a heat pump water heater falls into the very small bin of the First Hour Rating (FHR) test. Double check input.'
- when HPXML::WaterHeaterUsageBinLow
- cop = 1.0005 * uef - 0.0789
- when HPXML::WaterHeaterUsageBinMedium
- cop = 1.0909 * uef - 0.0868
- when HPXML::WaterHeaterUsageBinHigh
- cop = 1.1022 * uef - 0.0877
- end
+ if water_heating_system.hpwh_voltage == HPXML::HPWHVoltage240
+ # Based on simulations of the UEF test procedure at varying COPs
+ if not water_heating_system.energy_factor.nil?
+ uef = (0.60522 + water_heating_system.energy_factor) / 1.2101
+ cop = 1.174536058 * uef
+ elsif not water_heating_system.uniform_energy_factor.nil?
+ uef = water_heating_system.uniform_energy_factor
+ case water_heating_system.usage_bin
+ when HPXML::WaterHeaterUsageBinVerySmall
+ fail 'It is unlikely that a heat pump water heater falls into the very small bin of the First Hour Rating (FHR) test. Double check input.'
+ when HPXML::WaterHeaterUsageBinLow
+ cop = 1.0005 * uef - 0.0789
+ when HPXML::WaterHeaterUsageBinMedium
+ cop = 1.0909 * uef - 0.0868
+ when HPXML::WaterHeaterUsageBinHigh
+ cop = 1.1022 * uef - 0.0877
+ end
+ end
+ elsif water_heating_system.hpwh_voltage == HPXML::HPWHVoltage120Dedicated
+ cop = 3.6
+ else # 120V shared
+ cop = 4.2
end
return cop
end
@@ -6826,8 +6865,17 @@ def self.get_branch_circuit_voltage_default_values(branch_circuit)
end
elsif component.is_a?(HPXML::PVSystem)
voltages << HPXML::ElectricPanelVoltage240
- elsif component.is_a?(HPXML::WaterHeatingSystem) ||
- component.is_a?(HPXML::ClothesDryer) ||
+ elsif component.is_a?(HPXML::WaterHeatingSystem)
+ if component.fuel_type == HPXML::FuelTypeElectricity
+ if component.hpwh_voltage.nil? # Not HPWH
+ voltages << HPXML::ElectricPanelVoltage240
+ elsif component.hpwh_voltage == HPXML::HPWHVoltage240
+ voltages << HPXML::ElectricPanelVoltage240
+ else # 120V HPWH
+ voltages << HPXML::ElectricPanelVoltage120
+ end
+ end
+ elsif component.is_a?(HPXML::ClothesDryer) ||
component.is_a?(HPXML::CookingRange)
if component.fuel_type == HPXML::FuelTypeElectricity
voltages << HPXML::ElectricPanelVoltage240
diff --git a/HPXMLtoOpenStudio/resources/hotwater_appliances.rb b/HPXMLtoOpenStudio/resources/hotwater_appliances.rb
index 4dc67aeb15..c0b71d90d8 100644
--- a/HPXMLtoOpenStudio/resources/hotwater_appliances.rb
+++ b/HPXMLtoOpenStudio/resources/hotwater_appliances.rb
@@ -380,6 +380,16 @@ def self.apply(runner, model, weather, spaces, hpxml_bldg, hpxml_header, schedul
hpxml_bldg.water_heating_systems.each do |water_heating_system|
non_solar_fraction = 1.0 - Waterheater.get_water_heater_solar_fraction(water_heating_system, hpxml_bldg)
+ hw_temp_schedule = nil
+ if water_heating_system.has_mixing_valve
+ hw_temp_schedule = Model.add_schedule_constant(
+ model,
+ name: 'hot water temperature schedule',
+ value: UnitConversions.convert(water_heating_system.mixing_valve_setpoint, 'F', 'C'),
+ limits: EPlus::ScheduleTypeLimitsTemperature
+ )
+ end
+
gpd_frac = water_heating_system.fraction_dhw_load_served # Fixtures fraction
if gpd_frac > 0
@@ -489,7 +499,7 @@ def self.apply(runner, model, weather, spaces, hpxml_bldg, hpxml_header, schedul
peak_flow_rate: unit_multiplier * cw_peak_flow * gpd_frac * non_solar_fraction,
flow_rate_schedule: water_cw_schedule,
water_use_connections: water_use_connections[water_heating_system.id],
- target_temperature_schedule: nil
+ target_temperature_schedule: hw_temp_schedule
)
cw_wue.additionalProperties.setFeature('HPXML_ID', water_heating_system.id) # Used by reporting measure
end
@@ -526,7 +536,7 @@ def self.apply(runner, model, weather, spaces, hpxml_bldg, hpxml_header, schedul
peak_flow_rate: unit_multiplier * dw_peak_flow * gpd_frac * non_solar_fraction,
flow_rate_schedule: water_dw_schedule,
water_use_connections: water_use_connections[water_heating_system.id],
- target_temperature_schedule: nil
+ target_temperature_schedule: hw_temp_schedule
)
dw_wue.additionalProperties.setFeature('HPXML_ID', water_heating_system.id) # Used by reporting measure
end
diff --git a/HPXMLtoOpenStudio/resources/hpxml.rb b/HPXMLtoOpenStudio/resources/hpxml.rb
index 1b1634b35c..741921c214 100644
--- a/HPXMLtoOpenStudio/resources/hpxml.rb
+++ b/HPXMLtoOpenStudio/resources/hpxml.rb
@@ -224,6 +224,10 @@ class HPXML < Object
HeatPumpSizingACCA = 'ACCA'
HeatPumpSizingHERS = 'HERS'
HeatPumpSizingMaxLoad = 'MaxLoad'
+ HPWHVoltage240 = '240V'
+ HPWHVoltage120 = '120V'
+ HPWHVoltage120Dedicated = '120V dedicated circuit'
+ HPWHVoltage120Shared = '120V shared circuit'
HVACCompressorTypeSingleStage = 'single stage'
HVACCompressorTypeTwoStage = 'two stage'
HVACCompressorTypeVariableSpeed = 'variable speed'
@@ -8595,6 +8599,7 @@ class WaterHeatingSystem < BaseElement
:energy_factor, # [Double] EnergyFactor (frac)
:uniform_energy_factor, # [Double] UniformEnergyFactor (frac)
:hpwh_operating_mode, # [String] HPWHOperatingMode (HPXML::WaterHeaterHPWHOperatingModeXXX)
+ :hpwh_voltage, # [String] HPWHVoltage (HPXML::HPWHVoltageXXX)
:hpwh_ducting_supply, # [String] HPWHDucting/SupplyAirSource (HPXML::LocationXXX)
:hpwh_ducting_exhaust, # [String] HPWHDucting/ExhaustAirTermination (HPXML::LocationXXX)
:first_hour_rating, # [Double] FirstHourRating (gal/hr)
@@ -8604,6 +8609,8 @@ class WaterHeatingSystem < BaseElement
:standby_loss_units, # [String] StandbyLoss/Units (HPXML::UnitsXXX)
:standby_loss_value, # [Double] StandbyLoss/Value
:temperature, # [Double] HotWaterTemperature (F)
+ :has_mixing_valve, # [Boolean] HasMixingValve
+ :mixing_valve_setpoint, # [Double] MixingValveSetpoint (F)
:uses_desuperheater, # [Boolean] UsesDesuperheater
:related_hvac_idref, # [String] RelatedHVACSystem/@idref
:tank_model_type, # [String] extension/TankModelType (HPXML::WaterHeaterTankModelTypeXXX)
@@ -8698,6 +8705,7 @@ def to_doc(building)
XMLHelper.add_element(water_heating_system, 'EnergyFactor', @energy_factor, :float, @energy_factor_isdefaulted) unless @energy_factor.nil?
XMLHelper.add_element(water_heating_system, 'UniformEnergyFactor', @uniform_energy_factor, :float) unless @uniform_energy_factor.nil?
XMLHelper.add_element(water_heating_system, 'HPWHOperatingMode', @hpwh_operating_mode, :string, @hpwh_operating_mode_isdefaulted) unless @hpwh_operating_mode.nil?
+ XMLHelper.add_element(water_heating_system, 'HPWHVoltage', @hpwh_voltage, :string, @hpwh_voltage_isdefaulted) unless @hpwh_voltage.nil?
if (not @hpwh_ducting_exhaust.nil?) || (not @hpwh_ducting_supply.nil?)
hpwh_ducting = XMLHelper.add_element(water_heating_system, 'HPWHDucting')
XMLHelper.add_element(hpwh_ducting, 'SupplyAirSource', @hpwh_ducting_supply, :string, @hpwh_ducting_supply_isdefaulted) unless @hpwh_ducting_supply.nil?
@@ -8717,6 +8725,8 @@ def to_doc(building)
XMLHelper.add_element(standby_loss, 'Value', @standby_loss_value, :float, @standby_loss_value_isdefaulted)
end
XMLHelper.add_element(water_heating_system, 'HotWaterTemperature', @temperature, :float, @temperature_isdefaulted) unless @temperature.nil?
+ XMLHelper.add_element(water_heating_system, 'HasMixingValve', @has_mixing_valve, :boolean, @has_mixing_valve_isdefaulted) unless @has_mixing_valve.nil?
+ XMLHelper.add_element(water_heating_system, 'MixingValveSetpoint', @mixing_valve_setpoint, :float, @mixing_valve_setpoint_isdefaulted) unless @mixing_valve_setpoint.nil?
XMLHelper.add_element(water_heating_system, 'UsesDesuperheater', @uses_desuperheater, :boolean) unless @uses_desuperheater.nil?
if not @related_hvac_idref.nil?
related_hvac_idref_el = XMLHelper.add_element(water_heating_system, 'RelatedHVACSystem')
@@ -8753,6 +8763,7 @@ def from_doc(water_heating_system)
@energy_factor = XMLHelper.get_value(water_heating_system, 'EnergyFactor', :float)
@uniform_energy_factor = XMLHelper.get_value(water_heating_system, 'UniformEnergyFactor', :float)
@hpwh_operating_mode = XMLHelper.get_value(water_heating_system, 'HPWHOperatingMode', :string)
+ @hpwh_voltage = XMLHelper.get_value(water_heating_system, 'HPWHVoltage', :string)
@hpwh_ducting_supply = XMLHelper.get_value(water_heating_system, 'HPWHDucting/SupplyAirSource', :string)
@hpwh_ducting_exhaust = XMLHelper.get_value(water_heating_system, 'HPWHDucting/ExhaustAirTermination', :string)
@first_hour_rating = XMLHelper.get_value(water_heating_system, 'FirstHourRating', :float)
@@ -8762,6 +8773,8 @@ def from_doc(water_heating_system)
@standby_loss_units = XMLHelper.get_value(water_heating_system, 'StandbyLoss/Units', :string)
@standby_loss_value = XMLHelper.get_value(water_heating_system, 'StandbyLoss/Value', :float)
@temperature = XMLHelper.get_value(water_heating_system, 'HotWaterTemperature', :float)
+ @has_mixing_valve = XMLHelper.get_value(water_heating_system, 'HasMixingValve', :boolean)
+ @mixing_valve_setpoint = XMLHelper.get_value(water_heating_system, 'MixingValveSetpoint', :float)
@uses_desuperheater = XMLHelper.get_value(water_heating_system, 'UsesDesuperheater', :boolean)
@related_hvac_idref = HPXML::get_idref(XMLHelper.get_element(water_heating_system, 'RelatedHVACSystem'))
@tank_model_type = XMLHelper.get_value(water_heating_system, 'extension/TankModelType', :string)
diff --git a/HPXMLtoOpenStudio/resources/hpxml_schematron/EPvalidator.sch b/HPXMLtoOpenStudio/resources/hpxml_schematron/EPvalidator.sch
index 1bff796892..da7c3bd134 100644
--- a/HPXMLtoOpenStudio/resources/hpxml_schematron/EPvalidator.sch
+++ b/HPXMLtoOpenStudio/resources/hpxml_schematron/EPvalidator.sch
@@ -2079,6 +2079,11 @@
Expected ../HotWaterDistribution
Expected ../WaterFixture
Expected WaterHeaterType to be 'storage water heater' or 'instantaneous water heater' or 'heat pump water heater' or 'space-heating boiler with storage tank' or 'space-heating boiler with tankless coil'
+ Expected Location to be 'conditioned space' or 'basement - unconditioned' or 'basement - conditioned' or 'attic - unvented' or 'attic - vented' or 'garage' or 'crawlspace - unvented' or 'crawlspace - vented' or 'crawlspace - conditioned' or 'other exterior' or 'other housing unit' or 'other heated space' or 'other multifamily buffer space' or 'other non-freezing space'
+ Expected FractionDHWLoadServed
+ Expected HotWaterTemperature to be greater than or equal to 105 deg-F
+ Expected MixingValveSetpoint to be greater than or equal to 105 deg-F
+ Expected MixingValveSetpoint to be less than or equal to HotWaterTemperature
@@ -2086,8 +2091,6 @@
[WaterHeatingSystemType=Tank]
Expected FuelType to be 'natural gas' or 'fuel oil' or 'fuel oil 1' or 'fuel oil 2' or 'fuel oil 4' or 'fuel oil 5/6' or 'diesel' or 'propane' or 'kerosene' or 'coal' or 'coke' or 'bituminous coal' or 'anthracite coal' or 'electricity' or 'wood' or 'wood pellets'
- Expected Location to be 'conditioned space' or 'basement - unconditioned' or 'basement - conditioned' or 'attic - unvented' or 'attic - vented' or 'garage' or 'crawlspace - unvented' or 'crawlspace - vented' or 'crawlspace - conditioned' or 'other exterior' or 'other housing unit' or 'other heated space' or 'other multifamily buffer space' or 'other non-freezing space'
- Expected FractionDHWLoadServed
Expected HeatingCapacity to be greater than 0.
Expected UniformEnergyFactor or EnergyFactor but not both
Expected UniformEnergyFactor to be less than 1
@@ -2100,7 +2103,6 @@
UniformEnergyFactor should typically be greater than or equal to 0.45.
EnergyFactor should typically be greater than or equal to 0.45.
Heating capacity should typically be greater than or equal to 1000 Btu/hr.
- Hot water setpoint should typically be greater than or equal to 110 deg-F.
@@ -2115,15 +2117,12 @@
[WaterHeatingSystemType=Tankless]
Expected FuelType to be 'natural gas' or 'fuel oil' or 'fuel oil 1' or 'fuel oil 2' or 'fuel oil 4' or 'fuel oil 5/6' or 'diesel' or 'propane' or 'kerosene' or 'coal' or 'coke' or 'bituminous coal' or 'anthracite coal' or 'electricity' or 'wood' or 'wood pellets'
- Expected Location to be 'conditioned space' or 'basement - unconditioned' or 'basement - conditioned' or 'attic - unvented' or 'attic - vented' or 'garage' or 'crawlspace - unvented' or 'crawlspace - vented' or 'crawlspace - conditioned' or 'other exterior' or 'other housing unit' or 'other heated space' or 'other multifamily buffer space' or 'other non-freezing space'
- Expected FractionDHWLoadServed
Expected UniformEnergyFactor or EnergyFactor but not both
Expected UniformEnergyFactor to be less than 1
Expected EnergyFactor to be less than 1
UniformEnergyFactor should typically be greater than or equal to 0.45.
EnergyFactor should typically be greater than or equal to 0.45.
- Hot water setpoint should typically be greater than or equal to 110 deg-F.
@@ -2131,8 +2130,6 @@
[WaterHeatingSystemType=HPWH]
Expected FuelType to be 'electricity'
- Expected Location to be 'conditioned space' or 'basement - unconditioned' or 'basement - conditioned' or 'attic - unvented' or 'attic - vented' or 'garage' or 'crawlspace - unvented' or 'crawlspace - vented' or 'crawlspace - conditioned' or 'other exterior' or 'other housing unit' or 'other heated space' or 'other multifamily buffer space' or 'other non-freezing space'
- Expected FractionDHWLoadServed
Expected HeatingCapacity to be greater than 0.
Expected UniformEnergyFactor or EnergyFactor but not both
Expected UniformEnergyFactor to be greater than 1
@@ -2142,8 +2139,6 @@
Expected extension/HPWHInConfinedSpaceWithoutMitigation to be 'true' or 'false'
extension/OperatingMode has been replaced by HPWHOperatingMode
-
- Hot water setpoint should typically be greater than or equal to 110 deg-F.
@@ -2161,16 +2156,12 @@
[WaterHeatingSystemType=CombiIndirect]
Expected no FuelType
- Expected Location to be 'conditioned space' or 'basement - unconditioned' or 'basement - conditioned' or 'attic - unvented' or 'attic - vented' or 'garage' or 'crawlspace - unvented' or 'crawlspace - vented' or 'crawlspace - conditioned' or 'other exterior' or 'other housing unit' or 'other heated space' or 'other multifamily buffer space' or 'other non-freezing space'
- Expected FractionDHWLoadServed
Expected no HeatingCapacity
Expected no UniformEnergyFactor
Expected no EnergyFactor
Expected no RecoveryEfficiency
Expected no UsesDesuperheater=true
Expected RelatedHVACSystem
-
- Hot water setpoint should typically be greater than or equal to 110 deg-F.
@@ -2178,9 +2169,7 @@
[WaterHeatingSystemType=CombiTanklessCoil]
Expected no FuelType
- Expected Location to be 'conditioned space' or 'basement - unconditioned' or 'basement - conditioned' or 'attic - unvented' or 'attic - vented' or 'garage' or 'crawlspace - unvented' or 'crawlspace - vented' or 'crawlspace - conditioned' or 'other exterior' or 'other housing unit' or 'other heated space' or 'other multifamily buffer space' or 'other non-freezing space'
Expected no TankVolume
- Expected FractionDHWLoadServed
Expected no HeatingCapacity
Expected no UniformEnergyFactor
Expected no EnergyFactor
@@ -2189,8 +2178,6 @@
Expected no StandbyLoss[Units="F/hr"]/Value
Expected no UsesDesuperheater=true
Expected RelatedHVACSystem
-
- Hot water setpoint should typically be greater than or equal to 110 deg-F.
diff --git a/HPXMLtoOpenStudio/resources/waterheater.rb b/HPXMLtoOpenStudio/resources/waterheater.rb
index d10143c097..54e4bfa397 100644
--- a/HPXMLtoOpenStudio/resources/waterheater.rb
+++ b/HPXMLtoOpenStudio/resources/waterheater.rb
@@ -194,8 +194,13 @@ def self.apply_hpwh(runner, model, spaces, hpxml_bldg, hpxml_header, water_heati
end
airflow_rate = 200.0 # cfm, average value measured across a few different units
- min_temp = 42.0 # F
- max_temp = 120.0 # F
+ if water_heating_system.hpwh_voltage == HPXML::HPWHVoltage240
+ min_temp = 42.0 # F
+ max_temp = 120.0 # F
+ else # 120V
+ min_temp = 37.0 # F, from spec sheet
+ max_temp = 145.0 # F, from spec sheet
+ end
# Coil:WaterHeating:AirToWaterHeatPump:Wrapped
coil = apply_hpwh_dxcoil(runner, model, water_heating_system, hpxml_bldg.elevation, obj_name, airflow_rate, unit_multiplier)
@@ -219,7 +224,7 @@ def self.apply_hpwh(runner, model, spaces, hpxml_bldg, hpxml_header, water_heati
fan.additionalProperties.setFeature('ObjectType', Constants::ObjectTypeWaterHeater) # Used by reporting measure
# WaterHeater:HeatPump:WrappedCondenser
- hpwh = apply_hpwh_wrapped_condenser(model, obj_name, coil, tank, fan, airflow_rate, hpwh_tamb, hpwh_rhamb, min_temp, max_temp, control_setpoint_schedule, unit_multiplier)
+ hpwh = apply_hpwh_wrapped_condenser(model, obj_name, water_heating_system, coil, tank, fan, airflow_rate, hpwh_tamb, hpwh_rhamb, min_temp, max_temp, control_setpoint_schedule, unit_multiplier)
hpwh.additionalProperties.setFeature('HPXML_ID', water_heating_system.id) # Used by infiltration program
# Get ducting info
@@ -909,6 +914,7 @@ def self.apply_solar_thermal(model, spaces, hpxml_bldg, plantloop_map)
#
# @param model [OpenStudio::Model::Model] OpenStudio Model object
# @param obj_name [String] Name for the OpenStudio object
+ # @param water_heating_system [HPXML::WaterHeatingSystem] The HPXML water heating system of interest
# @param coil [OpenStudio::Model::CoilWaterHeatingAirToWaterHeatPumpWrapped] The HPWH DX coil
# @param tank [OpenStudio::Model::WaterHeaterStratified] The HPWH storage tank
# @param fan [OpenStudio::Model::FanSystemModel] The HPWH fan
@@ -920,10 +926,14 @@ def self.apply_solar_thermal(model, spaces, hpxml_bldg, plantloop_map)
# @param control_setpoint_schedule [OpenStudio::Model::ScheduleConstant or OpenStudio::Model::ScheduleRuleset] Setpoint temperature schedule (controlled)
# @param unit_multiplier [Integer] Number of similar dwelling units
# @return [OpenStudio::Model::WaterHeaterHeatPumpWrappedCondenser] The HPWH object
- def self.apply_hpwh_wrapped_condenser(model, obj_name, coil, tank, fan, airflow_rate, hpwh_tamb, hpwh_rhamb, min_temp, max_temp, control_setpoint_schedule, unit_multiplier)
+ def self.apply_hpwh_wrapped_condenser(model, obj_name, water_heating_system, coil, tank, fan, airflow_rate, hpwh_tamb, hpwh_rhamb, min_temp, max_temp, control_setpoint_schedule, unit_multiplier)
hpwh = OpenStudio::Model::WaterHeaterHeatPumpWrappedCondenser.new(model, coil, tank, fan, control_setpoint_schedule, model.alwaysOnDiscreteSchedule)
hpwh.setName("#{obj_name} hpwh")
- hpwh.setDeadBandTemperatureDifference(3.89)
+ if water_heating_system.hpwh_voltage == HPXML::HPWHVoltage240
+ hpwh.setDeadBandTemperatureDifference(3.89)
+ else
+ hpwh.setDeadBandTemperatureDifference(5.0)
+ end
hpwh.setCondenserBottomLocation((1.0 - (12 - 0.5) / 12.0) * tank.tankHeight.get) # in the 12th node of a 12-node tank (counting from top)
hpwh.setCondenserTopLocation((1.0 - (6 - 0.5) / 12.0) * tank.tankHeight.get) # in the 6th node of a 12-node tank (counting from top)
hpwh.setEvaporatorAirFlowRate(UnitConversions.convert(airflow_rate * unit_multiplier, 'ft^3/min', 'm^3/s'))
@@ -940,7 +950,11 @@ def self.apply_hpwh_wrapped_condenser(model, obj_name, coil, tank, fan, airflow_
hpwh.setParasiticHeatRejectionLocation('Outdoors')
hpwh.setTankElementControlLogic('MutuallyExclusive')
hpwh.setControlSensor1HeightInStratifiedTank((1.0 - (3 - 0.5) / 12.0) * tank.tankHeight.get) # in the 3rd node of a 12-node tank (counting from top)
- hpwh.setControlSensor1Weight(0.75)
+ if water_heating_system.hpwh_voltage == HPXML::HPWHVoltage240
+ hpwh.setControlSensor1Weight(0.75)
+ else
+ hpwh.setControlSensor1Weight(0.5)
+ end
hpwh.setControlSensor2HeightInStratifiedTank((1.0 - (9 - 0.5) / 12.0) * tank.tankHeight.get) # in the 9th node of a 12-node tank (counting from top)
return hpwh
@@ -958,17 +972,27 @@ def self.apply_hpwh_wrapped_condenser(model, obj_name, coil, tank, fan, airflow_
# @return [OpenStudio::Model::CoilWaterHeatingAirToWaterHeatPumpWrapped] The HPWH DX coil
def self.apply_hpwh_dxcoil(runner, model, water_heating_system, elevation, obj_name, airflow_rate, unit_multiplier)
# Curves
+ if water_heating_system.hpwh_voltage == HPXML::HPWHVoltage240
+ cap_coeff = [0.563, 0.0437, 0.000039, 0.0055, -0.000148, -0.000145]
+ cop_coeff = [1.1332, 0.063, -0.0000979, -0.00972, -0.0000214, -0.000686]
+ elsif water_heating_system.hpwh_voltage == HPXML::HPWHVoltage120Dedicated
+ cap_coeff = [0.636, 0.0227, 0.000406, -0.000437, 0.0, 0.0]
+ cop_coeff = [1.1798, 0.030, 0.0002063, -0.01935, 0.0001341, -0.000303]
+ else # 120V shared
+ cap_coeff = [0.813, 0.0160, 0.000537, 0.002032, -0.000086, -0.000069]
+ cop_coeff = [1.0132, 0.044, 0.0000117, -0.01113, 0.0000369, -0.000498]
+ end
hpwh_cap = Model.add_curve_biquadratic(
model,
name: 'HPWH-Cap-fT',
- coeff: [0.563, 0.0437, 0.000039, 0.0055, -0.000148, -0.000145],
+ coeff: cap_coeff,
min_x: 0, max_x: 100, min_y: 0, max_y: 100
)
hpwh_cop = Model.add_curve_biquadratic(
model,
name: 'HPWH-COP-fT',
- coeff: [1.1332, 0.063, -0.0000979, -0.00972, -0.0000214, -0.000686],
+ coeff: cop_coeff,
min_x: 0, max_x: 100, min_y: 0, max_y: 100
)
@@ -1058,6 +1082,7 @@ def self.apply_hpwh_stratified_tank(model, water_heating_system, obj_name, solar
# https://neea.org/img/documents/hpwh-lab-report_ao-smith_hptu_12-09-2015.pdf.
# More recent products do not show much change to UA values, see 2021 report:
# https://neea.org/img/documents/Laboratory-Assessment-of-Rheem-Generation-5-Series-HPWH.pdf.
+ # FIXME: Is this close enough to the right value for 120V, or do we need new UA values?
if water_heating_system.tank_volume <= 58.0
tank_ua = 3.6 # Btu/hr-F
elsif water_heating_system.tank_volume <= 73.0
diff --git a/HPXMLtoOpenStudio/tests/test_defaults.rb b/HPXMLtoOpenStudio/tests/test_defaults.rb
index ea6a8d25e4..513b2efaa9 100644
--- a/HPXMLtoOpenStudio/tests/test_defaults.rb
+++ b/HPXMLtoOpenStudio/tests/test_defaults.rb
@@ -3520,11 +3520,13 @@ def test_storage_water_heaters
wh.tank_model_type = HPXML::WaterHeaterTankModelTypeStratified
wh.first_hour_rating = nil
wh.usage_bin = nil
+ wh.has_mixing_valve = true
+ wh.mixing_valve_setpoint = 108
end
XMLHelper.write_file(hpxml.to_doc, @tmp_hpxml_path)
_default_hpxml, default_hpxml_bldg = _test_measure()
_test_default_storage_water_heater_values(default_hpxml_bldg,
- [true, 15000.0, 44.0, 0.95, HPXML::LocationConditionedSpace, 111, 0.90, HPXML::WaterHeaterTankModelTypeStratified])
+ [true, 15000.0, 44.0, 0.95, HPXML::LocationConditionedSpace, 111, 0.90, HPXML::WaterHeaterTankModelTypeStratified, true, 108])
# Test inputs not overridden by defaults w/ Usage Bin
hpxml_bldg.water_heating_systems.each do |wh|
@@ -3557,11 +3559,12 @@ def test_storage_water_heaters
wh.tank_model_type = nil
wh.first_hour_rating = nil
wh.usage_bin = nil
+ wh.mixing_valve_setpoint = nil
end
XMLHelper.write_file(hpxml.to_doc, @tmp_hpxml_path)
_default_hpxml, default_hpxml_bldg = _test_measure()
_test_default_storage_water_heater_values(default_hpxml_bldg,
- [false, 18766.7, 50.0, 0.98, HPXML::LocationBasementConditioned, 125, 0.9, HPXML::WaterHeaterTankModelTypeMixed])
+ [false, 18766.7, 50.0, 0.98, HPXML::LocationBasementConditioned, 125, 0.9, HPXML::WaterHeaterTankModelTypeMixed, true, 125])
# Test defaults w/ 5-bedroom house & electric storage water heater
hpxml, hpxml_bldg = _create_hpxml('base-enclosure-beds-5.xml')
@@ -3573,11 +3576,12 @@ def test_storage_water_heaters
wh.location = nil
wh.temperature = nil
wh.tank_model_type = nil
+ wh.has_mixing_valve = nil
end
XMLHelper.write_file(hpxml.to_doc, @tmp_hpxml_path)
_default_hpxml, default_hpxml_bldg = _test_measure()
_test_default_storage_water_heater_values(default_hpxml_bldg,
- [false, 18766.7, 66.0, 0.98, HPXML::LocationBasementConditioned, 125, 0.94, HPXML::WaterHeaterTankModelTypeMixed])
+ [false, 18766.7, 66.0, 0.98, HPXML::LocationBasementConditioned, 125, 0.94, HPXML::WaterHeaterTankModelTypeMixed, false, nil])
# Test defaults w/ 3-bedroom house & 2 storage water heaters (1 electric and 1 natural gas)
hpxml, hpxml_bldg = _create_hpxml('base-dhw-multiple.xml')
@@ -3591,12 +3595,13 @@ def test_storage_water_heaters
wh.location = nil
wh.temperature = nil
wh.tank_model_type = nil
+ wh.has_mixing_valve = nil
end
XMLHelper.write_file(hpxml.to_doc, @tmp_hpxml_path)
_default_hpxml, default_hpxml_bldg = _test_measure()
_test_default_storage_water_heater_values(default_hpxml_bldg,
- [false, 15354.6, 50.0, 0.98, HPXML::LocationBasementConditioned, 125, 0.94, HPXML::WaterHeaterTankModelTypeMixed],
- [false, 36000.0, 40.0, 0.757, HPXML::LocationBasementConditioned, 125, 0.59, HPXML::WaterHeaterTankModelTypeMixed])
+ [false, 15354.6, 50.0, 0.98, HPXML::LocationBasementConditioned, 125, 0.94, HPXML::WaterHeaterTankModelTypeMixed, false, nil],
+ [false, 36000.0, 40.0, 0.757, HPXML::LocationBasementConditioned, 125, 0.59, HPXML::WaterHeaterTankModelTypeMixed, false, nil])
end
def test_tankless_water_heaters
@@ -3631,33 +3636,59 @@ def test_heat_pump_water_heaters
hpxml_bldg.water_heating_systems[0].backup_heating_capacity = 5000.0
hpxml_bldg.water_heating_systems[0].hpwh_confined_space_without_mitigation = true
hpxml_bldg.water_heating_systems[0].hpwh_containment_volume = 800.0
+ hpxml_bldg.water_heating_systems[0].has_mixing_valve = true
+ hpxml_bldg.water_heating_systems[0].mixing_valve_setpoint = 120
XMLHelper.write_file(hpxml.to_doc, @tmp_hpxml_path)
_default_hpxml, default_hpxml_bldg = _test_measure()
- _test_default_heat_pump_water_heater_values(default_hpxml_bldg, [44.0, HPXML::WaterHeaterHPWHOperatingModeHeatPumpOnly, 4000.0, 5000.0, true])
+ _test_default_heat_pump_water_heater_values(default_hpxml_bldg, [44.0, HPXML::WaterHeaterHPWHOperatingModeHeatPumpOnly, HPXML::HPWHVoltage240, 4000.0, 5000.0, true, true, 120])
# Test defaults
hpxml_bldg.water_heating_systems[0].tank_volume = nil
hpxml_bldg.water_heating_systems[0].hpwh_operating_mode = nil
+ hpxml_bldg.water_heating_systems[0].hpwh_voltage = nil
hpxml_bldg.water_heating_systems[0].heating_capacity = nil
hpxml_bldg.water_heating_systems[0].backup_heating_capacity = nil
hpxml_bldg.water_heating_systems[0].hpwh_confined_space_without_mitigation = nil
+ hpxml_bldg.water_heating_systems[0].has_mixing_valve = nil
+ hpxml_bldg.water_heating_systems[0].mixing_valve_setpoint = nil
XMLHelper.write_file(hpxml.to_doc, @tmp_hpxml_path)
_default_hpxml, default_hpxml_bldg = _test_measure()
- _test_default_heat_pump_water_heater_values(default_hpxml_bldg, [66.0, HPXML::WaterHeaterHPWHOperatingModeHybridAuto, 6366.0, 15355.0, false])
+ _test_default_heat_pump_water_heater_values(default_hpxml_bldg, [66.0, HPXML::WaterHeaterHPWHOperatingModeHybridAuto, HPXML::HPWHVoltage240, 6366.0, 15355.0, false, false, nil])
+
+ # Test defaults w/ 120V dedicated circuit
+ hpxml_bldg.water_heating_systems[0].hpwh_voltage = HPXML::HPWHVoltage120Dedicated
+ hpxml_bldg.water_heating_systems[0].mixing_valve_setpoint = 120
+ XMLHelper.write_file(hpxml.to_doc, @tmp_hpxml_path)
+ _default_hpxml, default_hpxml_bldg = _test_measure()
+ _test_default_heat_pump_water_heater_values(default_hpxml_bldg, [66.0, HPXML::WaterHeaterHPWHOperatingModeHybridAuto, HPXML::HPWHVoltage120Dedicated, 5184.0, 0.0, false, true, 120])
+
+ # Test defaults w/ 120V shared circuit
+ hpxml_bldg.water_heating_systems[0].hpwh_voltage = HPXML::HPWHVoltage120Shared
+ hpxml_bldg.water_heating_systems[0].mixing_valve_setpoint = nil
+ XMLHelper.write_file(hpxml.to_doc, @tmp_hpxml_path)
+ _default_hpxml, default_hpxml_bldg = _test_measure()
+ _test_default_heat_pump_water_heater_values(default_hpxml_bldg, [66.0, HPXML::WaterHeaterHPWHOperatingModeHybridAuto, HPXML::HPWHVoltage120Shared, 5116.0, 0.0, false, true, 125])
+
+ # Test defaults w/ 120V (unspecified circuit)
+ hpxml_bldg.water_heating_systems[0].hpwh_voltage = HPXML::HPWHVoltage120
+ XMLHelper.write_file(hpxml.to_doc, @tmp_hpxml_path)
+ _default_hpxml, default_hpxml_bldg = _test_measure()
+ _test_default_heat_pump_water_heater_values(default_hpxml_bldg, [66.0, HPXML::WaterHeaterHPWHOperatingModeHybridAuto, HPXML::HPWHVoltage120, 5116.0, 0.0, false, true, 125])
# Test defaults w/ num occupants = 1, num bedrooms = 1
+ hpxml_bldg.water_heating_systems[0].hpwh_voltage = nil
hpxml_bldg.building_construction.number_of_bedrooms = 1
hpxml_bldg.building_occupancy.number_of_residents = 1
XMLHelper.write_file(hpxml.to_doc, @tmp_hpxml_path)
_default_hpxml, default_hpxml_bldg = _test_measure()
- _test_default_heat_pump_water_heater_values(default_hpxml_bldg, [50.0, HPXML::WaterHeaterHPWHOperatingModeHybridAuto, 6366.0, 15355.0, false])
+ _test_default_heat_pump_water_heater_values(default_hpxml_bldg, [50.0, HPXML::WaterHeaterHPWHOperatingModeHybridAuto, HPXML::HPWHVoltage240, 6366.0, 15355.0, false, false, nil])
# Test defaults w/ num occupants = 10, num bedrooms = 1
hpxml_bldg.building_construction.number_of_bedrooms = 1
hpxml_bldg.building_occupancy.number_of_residents = 10
XMLHelper.write_file(hpxml.to_doc, @tmp_hpxml_path)
_default_hpxml, default_hpxml_bldg = _test_measure()
- _test_default_heat_pump_water_heater_values(default_hpxml_bldg, [80.0, HPXML::WaterHeaterHPWHOperatingModeHybridAuto, 6366.0, 15355.0, false])
+ _test_default_heat_pump_water_heater_values(default_hpxml_bldg, [80.0, HPXML::WaterHeaterHPWHOperatingModeHybridAuto, HPXML::HPWHVoltage240, 6366.0, 15355.0, false, false, nil])
end
def test_indirect_water_heaters
@@ -6327,7 +6358,7 @@ def _test_default_storage_water_heater_values(hpxml_bldg, *expected_wh_values)
storage_water_heaters = hpxml_bldg.water_heating_systems.select { |w| w.water_heater_type == HPXML::WaterHeaterTypeStorage }
assert_equal(expected_wh_values.size, storage_water_heaters.size)
storage_water_heaters.each_with_index do |wh_system, idx|
- is_shared, heating_capacity, tank_volume, recovery_efficiency, location, temperature, efficiency, tank_model_type = expected_wh_values[idx]
+ is_shared, heating_capacity, tank_volume, recovery_efficiency, location, temperature, efficiency, tank_model_type, has_mix_valve, mix_valve_setpoint = expected_wh_values[idx]
assert_equal(is_shared, wh_system.is_shared_system)
assert_in_epsilon(heating_capacity, wh_system.heating_capacity, 0.01)
@@ -6341,6 +6372,12 @@ def _test_default_storage_water_heater_values(hpxml_bldg, *expected_wh_values)
assert_equal(efficiency, wh_system.energy_factor)
end
assert_equal(tank_model_type, wh_system.tank_model_type)
+ assert_equal(has_mix_valve, wh_system.has_mixing_valve)
+ if mix_valve_setpoint.nil?
+ assert_nil(wh_system.mixing_valve_setpoint)
+ else
+ assert_equal(mix_valve_setpoint, wh_system.mixing_valve_setpoint)
+ end
end
end
@@ -6358,13 +6395,20 @@ def _test_default_heat_pump_water_heater_values(hpxml_bldg, *expected_wh_values)
heat_pump_water_heaters = hpxml_bldg.water_heating_systems.select { |w| w.water_heater_type == HPXML::WaterHeaterTypeHeatPump }
assert_equal(expected_wh_values.size, heat_pump_water_heaters.size)
heat_pump_water_heaters.each_with_index do |wh_system, idx|
- tank_volume, operating_mode, htg_cap, backup_htg_cap, hpwh_confined_space_without_mitigation = expected_wh_values[idx]
+ tank_volume, operating_mode, voltage, htg_cap, backup_htg_cap, hpwh_confined, has_mix_valve, mix_valve_setpoint = expected_wh_values[idx]
assert_equal(tank_volume, wh_system.tank_volume)
assert_equal(operating_mode, wh_system.hpwh_operating_mode)
+ assert_equal(voltage, wh_system.hpwh_voltage)
assert_in_epsilon(htg_cap, wh_system.heating_capacity, 0.01)
assert_in_epsilon(backup_htg_cap, wh_system.backup_heating_capacity, 0.01)
- assert_equal(hpwh_confined_space_without_mitigation, wh_system.hpwh_confined_space_without_mitigation)
+ assert_equal(hpwh_confined, wh_system.hpwh_confined_space_without_mitigation)
+ assert_equal(has_mix_valve, wh_system.has_mixing_valve)
+ if mix_valve_setpoint.nil?
+ assert_nil(wh_system.mixing_valve_setpoint)
+ else
+ assert_equal(mix_valve_setpoint, wh_system.mixing_valve_setpoint)
+ end
end
end
diff --git a/HPXMLtoOpenStudio/tests/test_electric_panel.rb b/HPXMLtoOpenStudio/tests/test_electric_panel.rb
index f2f6f175d5..58ca0404f1 100644
--- a/HPXMLtoOpenStudio/tests/test_electric_panel.rb
+++ b/HPXMLtoOpenStudio/tests/test_electric_panel.rb
@@ -636,6 +636,18 @@ def test_water_heater_hpwh_without_backup
_test_occupied_spaces(hpxml_bldg, [HPXML::ElectricPanelLoadTypeWaterHeater], 2)
end
+ def test_water_heater_hpwh_120v
+ args_hash = { 'hpxml_path' => File.absolute_path(@tmp_hpxml_path),
+ 'skip_validation' => true }
+
+ hpxml, _hpxml_bldg = _create_hpxml('base-dhw-tank-heat-pump-120v.xml')
+ XMLHelper.write_file(hpxml.to_doc, @tmp_hpxml_path)
+ _model, _hpxml, hpxml_bldg = _test_measure(args_hash)
+
+ _test_service_feeder_power(hpxml_bldg, HPXML::ElectricPanelLoadTypeWaterHeater, 1218)
+ _test_occupied_spaces(hpxml_bldg, [HPXML::ElectricPanelLoadTypeWaterHeater], 1)
+ end
+
def test_clothes_dryer_conventional
args_hash = { 'hpxml_path' => File.absolute_path(@tmp_hpxml_path),
'skip_validation' => true }
diff --git a/HPXMLtoOpenStudio/tests/test_hotwater_appliance.rb b/HPXMLtoOpenStudio/tests/test_hotwater_appliance.rb
index 128bd04100..736c240676 100644
--- a/HPXMLtoOpenStudio/tests/test_hotwater_appliance.rb
+++ b/HPXMLtoOpenStudio/tests/test_hotwater_appliance.rb
@@ -109,6 +109,21 @@ def get_wu_gpd(model, name)
end
end
+ def get_wu_target_temp(model, name)
+ target_temps = []
+ model.getWaterUseEquipments.each do |wue|
+ next unless wue.waterUseEquipmentDefinition.endUseSubcategory.start_with? name
+ next unless wue.waterUseEquipmentDefinition.targetTemperatureSchedule.is_initialized
+
+ target_temps << UnitConversions.convert(wue.waterUseEquipmentDefinition.targetTemperatureSchedule.get.to_ScheduleConstant.get.value, 'C', 'F')
+ end
+ if target_temps.empty?
+ return
+ else
+ return target_temps.sum(0.0) / target_temps.size
+ end
+ end
+
def test_base
hpxml_names = ['base.xml',
'base-misc-usage-multiplier.xml']
@@ -179,6 +194,13 @@ def test_base
assert_in_delta(23.15, model.getSiteWaterMainsTemperature.maximumDifferenceInMonthlyAverageOutdoorAirTemperatures.get, 0.01)
assert_in_delta(1.0, model.getSiteWaterMainsTemperature.temperatureMultiplier, 0.01)
assert_in_delta(0.0, model.getSiteWaterMainsTemperature.temperatureOffset, 0.01)
+
+ # target temperatures
+ mw_temp = 105 # deg-F
+ assert_in_delta(mw_temp, get_wu_target_temp(model, Constants::ObjectTypeFixtures), 0.01)
+ assert_in_delta(mw_temp, get_wu_target_temp(model, Constants::ObjectTypeDistributionWaste), 0.01)
+ assert_nil(get_wu_target_temp(model, Constants::ObjectTypeDishwasher))
+ assert_nil(get_wu_target_temp(model, Constants::ObjectTypeClothesWasher))
end
end
@@ -466,6 +488,20 @@ def test_dhw_recirc_temp
assert_in_delta(pump_kwh_yr, get_ee_kwh(model, Constants::ObjectTypeHotWaterRecircPump), 0.1)
end
+ def test_dhw_mixing_valve
+ args_hash = {}
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-dhw-setpoint-temperature-mixing-valve.xml'))
+ model, _hpxml, hpxml_bldg = _test_measure(args_hash)
+
+ # target temperatures
+ mw_temp = 105 # deg-F
+ hw_temp = hpxml_bldg.water_heating_systems[0].mixing_valve_setpoint
+ assert_in_delta(mw_temp, get_wu_target_temp(model, Constants::ObjectTypeFixtures), 0.01)
+ assert_in_delta(mw_temp, get_wu_target_temp(model, Constants::ObjectTypeDistributionWaste), 0.01)
+ assert_in_delta(hw_temp, get_wu_target_temp(model, Constants::ObjectTypeDishwasher), 0.01)
+ assert_in_delta(hw_temp, get_wu_target_temp(model, Constants::ObjectTypeClothesWasher), 0.01)
+ end
+
def test_appliances_none
args_hash = {}
args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-appliances-none.xml'))
diff --git a/HPXMLtoOpenStudio/tests/test_validation.rb b/HPXMLtoOpenStudio/tests/test_validation.rb
index f7cc2fd8d1..bb1fa7fa99 100644
--- a/HPXMLtoOpenStudio/tests/test_validation.rb
+++ b/HPXMLtoOpenStudio/tests/test_validation.rb
@@ -76,6 +76,9 @@ def test_schema_schematron_error_messages
'dhw-frac-load-served' => ['Expected sum(FractionDHWLoadServed) to be 1 [context: /HPXML/Building/BuildingDetails, id: "MyBuilding"]'],
'dhw-invalid-ef-tank' => ['Expected EnergyFactor to be less than 1 [context: /HPXML/Building/BuildingDetails/Systems/WaterHeating/WaterHeatingSystem[WaterHeaterType="storage water heater"], id: "WaterHeatingSystem1"]'],
'dhw-invalid-uef-tank-heat-pump' => ['Expected UniformEnergyFactor to be greater than 1 [context: /HPXML/Building/BuildingDetails/Systems/WaterHeating/WaterHeatingSystem[WaterHeaterType="heat pump water heater"], id: "WaterHeatingSystem1"]'],
+ 'dhw-mixing-valve-setpoint-high' => ['Expected MixingValveSetpoint to be less than or equal to HotWaterTemperature'],
+ 'dhw-mixing-valve-setpoint-low' => ['Expected MixingValveSetpoint to be greater than or equal to 105 deg-F'],
+ 'dhw-setpoint-low' => ['Expected HotWaterTemperature to be greater than or equal to 105 deg-F'],
'dishwasher-location' => ['A location is specified as "garage" but no surfaces were found adjacent to this space type.'],
'duct-leakage-cfm25' => ["The value '-2.0' is less than the minimum value allowed",
"The value '-3.0' is less than the minimum value allowed"],
@@ -326,6 +329,16 @@ def test_schema_schematron_error_messages
when 'dhw-invalid-uef-tank-heat-pump'
hpxml, hpxml_bldg = _create_hpxml('base-dhw-tank-heat-pump.xml')
hpxml_bldg.water_heating_systems[0].uniform_energy_factor = 1.0
+ when 'dhw-mixing-valve-setpoint-high'
+ hpxml, hpxml_bldg = _create_hpxml('base.xml')
+ hpxml_bldg.water_heating_systems[0].temperature = 130
+ hpxml_bldg.water_heating_systems[0].mixing_valve_setpoint = 131
+ when 'dhw-mixing-valve-setpoint-low'
+ hpxml, hpxml_bldg = _create_hpxml('base.xml')
+ hpxml_bldg.water_heating_systems[0].mixing_valve_setpoint = 100
+ when 'dhw-setpoint-low'
+ hpxml, hpxml_bldg = _create_hpxml('base.xml')
+ hpxml_bldg.water_heating_systems[0].temperature = 100
when 'dishwasher-location'
hpxml, hpxml_bldg = _create_hpxml('base.xml')
hpxml_bldg.dishwashers[0].location = HPXML::LocationGarage
@@ -991,7 +1004,6 @@ def test_schema_schematron_warning_messages
'EnergyFactor should typically be greater than or equal to 0.45.',
'EnergyFactor should typically be greater than or equal to 0.45.',
'No space cooling specified, the model will not include space cooling energy use.'],
- 'dhw-setpoint-low' => ['Hot water setpoint should typically be greater than or equal to 110 deg-F.'],
'erv-atre-low' => ['Adjusted total recovery efficiency should typically be at least half of the adjusted sensible recovery efficiency.'],
'erv-tre-low' => ['Total recovery efficiency should typically be at least half of the sensible recovery efficiency.'],
'ev-charging-methods' => ['Electric vehicle charging was specified as both a PlugLoad and a Vehicle, the latter will be ignored.'],
@@ -1094,9 +1106,6 @@ def test_schema_schematron_warning_messages
water_heating_system.energy_factor = 0.1
end
end
- when 'dhw-setpoint-low'
- hpxml, hpxml_bldg = _create_hpxml('base.xml')
- hpxml_bldg.water_heating_systems[0].temperature = 100
when 'erv-atre-low'
hpxml, hpxml_bldg = _create_hpxml('base-mechvent-erv-atre-asre.xml')
hpxml_bldg.ventilation_fans[0].total_recovery_efficiency_adjusted = 0.1
diff --git a/HPXMLtoOpenStudio/tests/test_water_heater.rb b/HPXMLtoOpenStudio/tests/test_water_heater.rb
index f176b1209b..09c6502df0 100644
--- a/HPXMLtoOpenStudio/tests/test_water_heater.rb
+++ b/HPXMLtoOpenStudio/tests/test_water_heater.rb
@@ -944,117 +944,59 @@ def test_tank_combi_tankless
end
def test_tank_heat_pump
- args_hash = {}
- args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-dhw-tank-heat-pump.xml'))
- model, _hpxml, hpxml_bldg = _test_measure(args_hash)
-
- # Get HPXML values
- water_heating_system = hpxml_bldg.water_heating_systems[0]
-
- # Expected value
- tank_volume = UnitConversions.convert(water_heating_system.tank_volume * 0.9, 'gal', 'm^3') # convert to actual volume
- fuel = EPlus.fuel_type(water_heating_system.fuel_type)
- u = 0.926
- ther_eff = 1.0
- cop = 3.731
- tank_height = 1.3343
- cap = 500.0 * cop # W
- backup_cap = 4500.0 # W
-
- # Check water heater
- assert_equal(1, model.getWaterHeaterHeatPumpWrappedCondensers.size)
- assert_equal(1, model.getWaterHeaterStratifieds.size)
- hpwh = model.getWaterHeaterHeatPumpWrappedCondensers[0]
- wh = hpwh.tank.to_WaterHeaterStratified.get
- coil = hpwh.dXCoil.to_CoilWaterHeatingAirToWaterHeatPumpWrapped.get
- assert_equal(fuel, wh.heaterFuelType)
- assert_equal('Schedule', wh.ambientTemperatureIndicator)
- assert_in_epsilon(tank_volume, wh.tankVolume.get, 0.01)
- assert_in_epsilon(tank_height, wh.tankHeight.get, 0.01)
- assert_in_epsilon(backup_cap, wh.heater1Capacity.get, 0.01)
- assert_in_epsilon(backup_cap, wh.heater2Capacity, 0.01)
- assert_in_epsilon(u, wh.uniformSkinLossCoefficientperUnitAreatoAmbientTemperature.get, 0.01)
- assert_in_epsilon(ther_eff, wh.heaterThermalEfficiency, 0.01)
-
- # Check heat pump cooling coil cop
- assert_in_epsilon(cop, coil.ratedCOP, 0.01)
- assert_in_epsilon(cap, coil.ratedHeatingCapacity, 0.01)
- end
-
- def test_tank_heat_pump_ef
- args_hash = {}
- args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-dhw-tank-heat-pump-ef.xml'))
- model, _hpxml, hpxml_bldg = _test_measure(args_hash)
-
- # Get HPXML values
- water_heating_system = hpxml_bldg.water_heating_systems[0]
-
- # Expected value
- tank_volume = UnitConversions.convert(water_heating_system.tank_volume * 0.9, 'gal', 'm^3') # convert to actual volume
- fuel = EPlus.fuel_type(water_heating_system.fuel_type)
- u = 0.92
- ther_eff = 1.0
- cop = 3.60
- tank_height = 1.5975
- cap = 500.0 * cop # W
- backup_cap = 4500.0 # W
-
- # Check water heater
- assert_equal(1, model.getWaterHeaterHeatPumpWrappedCondensers.size)
- assert_equal(1, model.getWaterHeaterStratifieds.size)
- hpwh = model.getWaterHeaterHeatPumpWrappedCondensers[0]
- wh = hpwh.tank.to_WaterHeaterStratified.get
- coil = hpwh.dXCoil.to_CoilWaterHeatingAirToWaterHeatPumpWrapped.get
- assert_equal(fuel, wh.heaterFuelType)
- assert_equal('Schedule', wh.ambientTemperatureIndicator)
- assert_in_epsilon(tank_volume, wh.tankVolume.get, 0.01)
- assert_in_epsilon(tank_height, wh.tankHeight.get, 0.01)
- assert_in_epsilon(backup_cap, wh.heater1Capacity.get, 0.01)
- assert_in_epsilon(backup_cap, wh.heater2Capacity, 0.01)
- assert_in_epsilon(u, wh.uniformSkinLossCoefficientperUnitAreatoAmbientTemperature.get, 0.01)
- assert_in_epsilon(ther_eff, wh.heaterThermalEfficiency, 0.01)
-
- # Check heat pump cooling coil cop
- assert_in_epsilon(cop, coil.ratedCOP, 0.01)
- assert_in_epsilon(cap, coil.ratedHeatingCapacity, 0.01)
- end
-
- def test_tank_heat_pump_capacities
- args_hash = {}
- args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-dhw-tank-heat-pump-capacities.xml'))
- model, _hpxml, hpxml_bldg = _test_measure(args_hash)
-
- # Get HPXML values
- water_heating_system = hpxml_bldg.water_heating_systems[0]
+ ['base-dhw-tank-heat-pump.xml',
+ 'base-dhw-tank-heat-pump-ef.xml',
+ 'base-dhw-tank-heat-pump-120v.xml',
+ 'base-dhw-tank-heat-pump-120v-dedicated-circuit.xml',
+ 'base-dhw-tank-heat-pump-capacities.xml'].each do |hpxml_name|
+ args_hash = {}
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, hpxml_name))
+ model, _hpxml, hpxml_bldg = _test_measure(args_hash)
- # Expected value
- tank_volume = UnitConversions.convert(water_heating_system.tank_volume * 0.9, 'gal', 'm^3') # convert to actual volume
- fuel = EPlus.fuel_type(water_heating_system.fuel_type)
- u = 0.926
- ther_eff = 1.0
- cop = 3.731
- tank_height = 1.3343
- cap = UnitConversions.convert(water_heating_system.heating_capacity, 'Btu/hr', 'W') # W
- backup_cap = UnitConversions.convert(water_heating_system.backup_heating_capacity, 'Btu/hr', 'W') # W
+ # Get HPXML values
+ water_heating_system = hpxml_bldg.water_heating_systems[0]
- # Check water heater
- assert_equal(1, model.getWaterHeaterHeatPumpWrappedCondensers.size)
- assert_equal(1, model.getWaterHeaterStratifieds.size)
- hpwh = model.getWaterHeaterHeatPumpWrappedCondensers[0]
- wh = hpwh.tank.to_WaterHeaterStratified.get
- coil = hpwh.dXCoil.to_CoilWaterHeatingAirToWaterHeatPumpWrapped.get
- assert_equal(fuel, wh.heaterFuelType)
- assert_equal('Schedule', wh.ambientTemperatureIndicator)
- assert_in_epsilon(tank_volume, wh.tankVolume.get, 0.01)
- assert_in_epsilon(tank_height, wh.tankHeight.get, 0.01)
- assert_in_epsilon(backup_cap, wh.heater1Capacity.get, 0.01)
- assert_in_epsilon(backup_cap, wh.heater2Capacity, 0.01)
- assert_in_epsilon(u, wh.uniformSkinLossCoefficientperUnitAreatoAmbientTemperature.get, 0.01)
- assert_in_epsilon(ther_eff, wh.heaterThermalEfficiency, 0.01)
+ # Expected value
+ tank_volume = UnitConversions.convert(water_heating_system.tank_volume * 0.9, 'gal', 'm^3') # convert to actual volume
+ fuel = EPlus.fuel_type(water_heating_system.fuel_type)
+ cap = UnitConversions.convert(water_heating_system.heating_capacity, 'Btu/hr', 'W') # W
+ backup_cap = UnitConversions.convert(water_heating_system.backup_heating_capacity, 'Btu/hr', 'W') # W
+ if hpxml_name == 'base-dhw-tank-heat-pump-ef.xml'
+ u = 0.92
+ cop = 3.60
+ tank_height = 1.5975
+ else
+ u = 0.926
+ if hpxml_name == 'base-dhw-tank-heat-pump-120v.xml'
+ cop = 4.2
+ elsif hpxml_name == 'base-dhw-tank-heat-pump-120v-dedicated-circuit.xml'
+ cop = 3.6
+ else
+ cop = 3.731
+ end
+ tank_height = 1.3343
+ end
+ ther_eff = 1.0
- # Check heat pump cooling coil cop
- assert_in_epsilon(cop, coil.ratedCOP, 0.01)
- assert_in_epsilon(cap, coil.ratedHeatingCapacity, 0.01)
+ # Check water heater
+ assert_equal(1, model.getWaterHeaterHeatPumpWrappedCondensers.size)
+ assert_equal(1, model.getWaterHeaterStratifieds.size)
+ hpwh = model.getWaterHeaterHeatPumpWrappedCondensers[0]
+ wh = hpwh.tank.to_WaterHeaterStratified.get
+ coil = hpwh.dXCoil.to_CoilWaterHeatingAirToWaterHeatPumpWrapped.get
+ assert_equal(fuel, wh.heaterFuelType)
+ assert_equal('Schedule', wh.ambientTemperatureIndicator)
+ assert_in_epsilon(tank_volume, wh.tankVolume.get, 0.01)
+ assert_in_epsilon(tank_height, wh.tankHeight.get, 0.01)
+ assert_in_epsilon(backup_cap, wh.heater1Capacity.get, 0.01)
+ assert_in_epsilon(backup_cap, wh.heater2Capacity, 0.01)
+ assert_in_epsilon(u, wh.uniformSkinLossCoefficientperUnitAreatoAmbientTemperature.get, 0.01)
+ assert_in_epsilon(ther_eff, wh.heaterThermalEfficiency, 0.01)
+
+ # Check heat pump cooling coil cop
+ assert_in_epsilon(cop, coil.ratedCOP, 0.01)
+ assert_in_epsilon(cap, coil.ratedHeatingCapacity, 0.01)
+ end
end
def test_tank_heat_pump_containment_volume_adjustment
diff --git a/docs/source/workflow_inputs.rst b/docs/source/workflow_inputs.rst
index fb213dc893..801f5d472f 100644
--- a/docs/source/workflow_inputs.rst
+++ b/docs/source/workflow_inputs.rst
@@ -4131,26 +4131,28 @@ Conventional Storage
Each conventional storage water heater is entered as a ``/HPXML/Building/BuildingDetails/Systems/WaterHeating/WaterHeatingSystem``.
- ============================================= ================= ============= ==================== ======== ======== =============================================
- Element Type Units Constraints Required Default Notes
- ============================================= ================= ============= ==================== ======== ======== =============================================
- ``SystemIdentifier`` id Yes Unique identifier
- ``FuelType`` string See [#]_ Yes Fuel type
- ``WaterHeaterType`` string storage water heater Yes Type of water heater
- ``Location`` string See [#]_ No See [#]_ Water heater location
- ``IsSharedSystem`` boolean No false Whether it serves multiple dwelling units or shared laundry room
- ``TankVolume`` double gal > 0 No See [#]_ Nominal tank volume
- ``FractionDHWLoadServed`` double frac >= 0, <= 1 [#]_ Yes Fraction of hot water load served [#]_
- ``HeatingCapacity`` double Btu/hr > 0 No See [#]_ Heating capacity
- ``UniformEnergyFactor`` or ``EnergyFactor`` double frac < 1 Yes EnergyGuide label rated efficiency
- ``UsageBin`` or ``FirstHourRating`` string or double str or gal/hr See [#]_ or > 0 No See [#]_ EnergyGuide label usage bin/first hour rating
- ``RecoveryEfficiency`` double frac > 0, <= 1 [#]_ No See [#]_ Recovery efficiency
- ``WaterHeaterInsulation/Jacket/JacketRValue`` double F-ft2-hr/Btu >= 0 No 0 R-value of additional tank insulation wrap
- ``HotWaterTemperature`` double F > 0 No 125 Water heater setpoint [#]_
- ``UsesDesuperheater`` boolean No false Presence of desuperheater? [#]_
- ``extension/TankModelType`` string See [#]_ No mixed Tank model type
- ``extension/NumberofBedroomsServed`` integer > NumberofBedrooms See [#]_ Number of bedrooms served directly or indirectly
- ============================================= ================= ============= ==================== ======== ======== =============================================
+ ============================================= ================= ============= ============================== ======== ======== =============================================
+ Element Type Units Constraints Required Default Notes
+ ============================================= ================= ============= ============================== ======== ======== =============================================
+ ``SystemIdentifier`` id Yes Unique identifier
+ ``FuelType`` string See [#]_ Yes Fuel type
+ ``WaterHeaterType`` string storage water heater Yes Type of water heater
+ ``Location`` string See [#]_ No See [#]_ Water heater location
+ ``IsSharedSystem`` boolean No false Whether it serves multiple dwelling units or shared laundry room
+ ``TankVolume`` double gal > 0 No See [#]_ Nominal tank volume
+ ``FractionDHWLoadServed`` double frac >= 0, <= 1 [#]_ Yes Fraction of hot water load served [#]_
+ ``HeatingCapacity`` double Btu/hr > 0 No See [#]_ Heating capacity
+ ``UniformEnergyFactor`` or ``EnergyFactor`` double frac < 1 Yes EnergyGuide label rated efficiency
+ ``UsageBin`` or ``FirstHourRating`` string or double str or gal/hr See [#]_ or > 0 No See [#]_ EnergyGuide label usage bin/first hour rating
+ ``RecoveryEfficiency`` double frac > 0, <= 1 [#]_ No See [#]_ Recovery efficiency
+ ``WaterHeaterInsulation/Jacket/JacketRValue`` double F-ft2-hr/Btu >= 0 No 0 R-value of additional tank insulation wrap
+ ``HotWaterTemperature`` double F >= 105 No 125 Water heater setpoint [#]_
+ ``HasMixingValve`` boolean No false Presence of a water heater mixing value?
+ ``MixingValveSetpoint`` double F >= 105, <= HotWaterTemperature No See [#]_ Temperature setpoint for the mixing valve
+ ``UsesDesuperheater`` boolean No false Presence of desuperheater? [#]_
+ ``extension/TankModelType`` string See [#]_ No mixed Tank model type
+ ``extension/NumberofBedroomsServed`` integer > NumberofBedrooms See [#]_ Number of bedrooms served directly or indirectly
+ ============================================= ================= ============= ============================== ======== ======== =============================================
.. [#] FuelType choices are "natural gas", "fuel oil", "fuel oil 1", "fuel oil 2", "fuel oil 4", "fuel oil 5/6", "diesel", "propane", "kerosene", "coal", "coke", "bituminous coal", "anthracite coal", "electricity", "wood", or "wood pellets".
.. [#] Location choices are "conditioned space", "basement - unconditioned", "basement - conditioned", "attic - unvented", "attic - vented", "garage", "crawlspace - unvented", "crawlspace - vented", "crawlspace - conditioned", "other exterior", "other housing unit", "other heated space", "other multifamily buffer space", or "other non-freezing space".
@@ -4178,6 +4180,7 @@ Each conventional storage water heater is entered as a ``/HPXML/Building/Buildin
\- **Non-electric, EnergyFactor >= 0.75**: 0.561 * EnergyFactor + 0.439
.. [#] The water heater setpoint can alternatively be defined using :ref:`schedules_detailed`.
+ .. [#] If MixingValveSetpoint not provided and HasMixingValve=true, defaults to the lesser of 125 deg-F and HotWaterTemperature.
.. [#] Additional desuperheater inputs are described in :ref:`water_heater_desuperheater`.
.. [#] TankModelType choices are "mixed" or "stratified". Only currently allowed if FuelType is "electricity".
.. [#] NumberofBedroomsServed only required if IsSharedSystem is true.
@@ -4191,21 +4194,23 @@ Tankless
Each instantaneous tankless water heater is entered as a ``/HPXML/Building/BuildingDetails/Systems/WaterHeating/WaterHeatingSystem``.
- =========================================== ======= ============ ========================== ============ ======== ==========================================================
- Element Type Units Constraints Required Default Notes
- =========================================== ======= ============ ========================== ============ ======== ==========================================================
- ``SystemIdentifier`` id Yes Unique identifier
- ``FuelType`` string See [#]_ Yes Fuel type
- ``WaterHeaterType`` string instantaneous water heater Yes Type of water heater
- ``Location`` string See [#]_ No See [#]_ Water heater location
- ``IsSharedSystem`` boolean No false Whether it serves multiple dwelling units or shared laundry room
- ``PerformanceAdjustment`` double frac >= 0, <= 1 No See [#]_ Multiplier on efficiency, typically to account for cycling
- ``FractionDHWLoadServed`` double frac >= 0, <= 1 [#]_ Yes Fraction of hot water load served [#]_
- ``UniformEnergyFactor`` or ``EnergyFactor`` double frac < 1 Yes EnergyGuide label rated efficiency
- ``HotWaterTemperature`` double F > 0 No 125 Water heater setpoint [#]_
- ``UsesDesuperheater`` boolean No false Presence of desuperheater? [#]_
- ``extension/NumberofBedroomsServed`` integer > NumberofBedrooms See [#]_ Number of bedrooms served directly or indirectly
- =========================================== ======= ============ ========================== ============ ======== ==========================================================
+ =========================================== ======= ============ ============================== ============ ======== ==========================================================
+ Element Type Units Constraints Required Default Notes
+ =========================================== ======= ============ ============================== ============ ======== ==========================================================
+ ``SystemIdentifier`` id Yes Unique identifier
+ ``FuelType`` string See [#]_ Yes Fuel type
+ ``WaterHeaterType`` string instantaneous water heater Yes Type of water heater
+ ``Location`` string See [#]_ No See [#]_ Water heater location
+ ``IsSharedSystem`` boolean No false Whether it serves multiple dwelling units or shared laundry room
+ ``PerformanceAdjustment`` double frac >= 0, <= 1 No See [#]_ Multiplier on efficiency, typically to account for cycling
+ ``FractionDHWLoadServed`` double frac >= 0, <= 1 [#]_ Yes Fraction of hot water load served [#]_
+ ``UniformEnergyFactor`` or ``EnergyFactor`` double frac < 1 Yes EnergyGuide label rated efficiency
+ ``HotWaterTemperature`` double F >= 105 No 125 Water heater setpoint [#]_
+ ``HasMixingValve`` boolean No false Presence of a water heater mixing value?
+ ``MixingValveSetpoint`` double F >= 105, <= HotWaterTemperature No See [#]_ Temperature setpoint for the mixing valve
+ ``UsesDesuperheater`` boolean No false Presence of desuperheater? [#]_
+ ``extension/NumberofBedroomsServed`` integer > NumberofBedrooms See [#]_ Number of bedrooms served directly or indirectly
+ =========================================== ======= ============ ============================== ============ ======== ==========================================================
.. [#] FuelType choices are "natural gas", "fuel oil", "fuel oil 1", "fuel oil 2", "fuel oil 4", "fuel oil 5/6", "diesel", "propane", "kerosene", "coal", "coke", "bituminous coal", "anthracite coal", "electricity", "wood", or "wood pellets".
.. [#] Location choices are "conditioned space", "basement - unconditioned", "basement - conditioned", "attic - unvented", "attic - vented", "garage", "crawlspace - unvented", "crawlspace - vented", "crawlspace - conditioned", "other exterior", "other housing unit", "other heated space", "other multifamily buffer space", or "other non-freezing space".
@@ -4221,6 +4226,7 @@ Each instantaneous tankless water heater is entered as a ``/HPXML/Building/Build
.. [#] FractionDHWLoadServed represents only the fraction of the hot water load associated with the hot water **fixtures**.
Additional hot water load from clothes washers/dishwashers will be automatically assigned to the appropriate water heater(s).
.. [#] The water heater setpoint can alternatively be defined using :ref:`schedules_detailed`.
+ .. [#] If MixingValveSetpoint not provided and HasMixingValve=true, defaults to the lesser of 125 deg-F and HotWaterTemperature.
.. [#] Additional desuperheater inputs are described in :ref:`water_heater_desuperheater`.
.. [#] NumberofBedroomsServed only required if IsSharedSystem is true.
Each dwelling unit w/zero bedrooms should be counted as 1 bedroom -- e.g., a value of 3 should be entered for a shared system serving 3 studio (zero bedroom) apartments.
@@ -4232,29 +4238,32 @@ Heat Pump
Each heat pump water heater is entered as a ``/HPXML/Building/BuildingDetails/Systems/WaterHeating/WaterHeatingSystem``.
- =================================================== ================ ============= ====================== ======== ============== =============================================
- Element Type Units Constraints Required Default Notes
- =================================================== ================ ============= ====================== ======== ============== =============================================
- ``SystemIdentifier`` id Yes Unique identifier
- ``FuelType`` string electricity Yes Fuel type
- ``WaterHeaterType`` string heat pump water heater Yes Type of water heater
- ``Location`` string See [#]_ No See [#]_ Water heater location
- ``IsSharedSystem`` boolean No false Whether it serves multiple dwelling units or shared laundry room
- ``TankVolume`` double gal > 0 No See [#]_ Nominal tank volume
- ``FractionDHWLoadServed`` double frac >= 0, <= 1 [#]_ Yes Fraction of hot water load served [#]_
- ``HeatingCapacity`` double Btu/hr > 0 No See [#]_ Heating output capacity
- ``BackupHeatingCapacity`` double Btu/hr >= 0 No 15355 (4.5 kW) Heating capacity of the electric resistance backup
- ``UniformEnergyFactor`` or ``EnergyFactor`` double frac > 1, <= 5 Yes EnergyGuide label rated efficiency
- ``HPWHDucting/ExhaustAirTermination`` string See [#]_ No The location where HPWH exhaust air is ducted to
- ``HPWHOperatingMode`` string See [#]_ No hybrid/auto Operating mode [#]_
- ``UsageBin`` or ``FirstHourRating`` string or double str or gal/hr See [#]_ or > 0 No See [#]_ EnergyGuide label usage bin/first hour rating
- ``WaterHeaterInsulation/Jacket/JacketRValue`` double F-ft2-hr/Btu >= 0 No 0 R-value of additional tank insulation wrap
- ``HotWaterTemperature`` double F > 0 No 125 Water heater setpoint [#]_
- ``UsesDesuperheater`` boolean No false Presence of desuperheater? [#]_
- ``extension/NumberofBedroomsServed`` integer > NumberofBedrooms See [#]_ Number of bedrooms served directly or indirectly
- ``extension/HPWHInConfinedSpaceWithoutMitigation`` boolean No false Whether HPWH is installed in confined space without mitigation [#]_
- ``extension/HPWHContainmentVolume`` double ft3 > 0 See [#]_ Containment volume of the space where HPWH is installed
- =================================================== ================ ============= ====================== ======== ============== =============================================
+ =================================================== ================ ============= ============================== ======== ============== =============================================
+ Element Type Units Constraints Required Default Notes
+ =================================================== ================ ============= ============================== ======== ============== =============================================
+ ``SystemIdentifier`` id Yes Unique identifier
+ ``FuelType`` string electricity Yes Fuel type
+ ``WaterHeaterType`` string heat pump water heater Yes Type of water heater
+ ``Location`` string See [#]_ No See [#]_ Water heater location
+ ``IsSharedSystem`` boolean No false Whether it serves multiple dwelling units or shared laundry room
+ ``TankVolume`` double gal > 0 No See [#]_ Nominal tank volume
+ ``FractionDHWLoadServed`` double frac >= 0, <= 1 [#]_ Yes Fraction of hot water load served [#]_
+ ``HeatingCapacity`` double Btu/hr > 0 No See [#]_ Heating output capacity
+ ``BackupHeatingCapacity`` double Btu/hr >= 0 No See [#]_ Heating capacity of the electric resistance backup
+ ``UniformEnergyFactor`` or ``EnergyFactor`` double frac > 1, <= 5 Yes EnergyGuide label rated efficiency
+ ``HPWHOperatingMode`` string See [#]_ No hybrid/auto HPWH operating mode [#]_
+ ``HPWHVoltage`` string See [#]_ No 240V HPWH voltage
+ ``HPWHDucting/ExhaustAirTermination`` string See [#]_ No The location where HPWH exhaust air is ducted to
+ ``UsageBin`` or ``FirstHourRating`` string or double str or gal/hr See [#]_ or > 0 No See [#]_ EnergyGuide label usage bin/first hour rating
+ ``WaterHeaterInsulation/Jacket/JacketRValue`` double F-ft2-hr/Btu >= 0 No 0 R-value of additional tank insulation wrap
+ ``HotWaterTemperature`` double F >= 105 No 125 Water heater setpoint [#]_
+ ``HasMixingValve`` boolean No See [#]_ Presence of a water heater mixing value?
+ ``MixingValveSetpoint`` double F >= 105, <= HotWaterTemperature No See [#]_ Temperature setpoint for the mixing valve
+ ``UsesDesuperheater`` boolean No false Presence of desuperheater? [#]_
+ ``extension/NumberofBedroomsServed`` integer > NumberofBedrooms See [#]_ Number of bedrooms served directly or indirectly
+ ``extension/HPWHInConfinedSpaceWithoutMitigation`` boolean No false Whether HPWH is installed in confined space without mitigation [#]_
+ ``extension/HPWHContainmentVolume`` double ft3 > 0 See [#]_ Containment volume of the space where HPWH is installed
+ =================================================== ================ ============= ============================== ======== ============== =============================================
.. [#] Location choices are "conditioned space", "basement - unconditioned", "basement - conditioned", "attic - unvented", "attic - vented", "garage", "crawlspace - unvented", "crawlspace - vented", "crawlspace - conditioned", "other exterior", "other housing unit", "other heated space", "other multifamily buffer space", or "other non-freezing space".
See :ref:`hpxml_locations` for descriptions.
@@ -4273,16 +4282,20 @@ Each heat pump water heater is entered as a ``/HPXML/Building/BuildingDetails/Sy
.. [#] The sum of all ``FractionDHWLoadServed`` (across all WaterHeatingSystems) must equal to 1.
.. [#] FractionDHWLoadServed represents only the fraction of the hot water load associated with the hot water **fixtures**.
Additional hot water load from clothes washers/dishwashers will be automatically assigned to the appropriate water heater(s).
- .. [#] If HeatingCapacity not provided, defaults to 1706 Btu/hr (0.5 kW) multiplied by the heat pump COP.
- .. [#] OpenStudio-HPXML currently only supports ExhaustAirTermination="outside" for heat pump water heaters located in conditioned space.
- Any other combination of ExhaustAirTermination value and water heater location will be ignored w/ a warning.
+ .. [#] If HeatingCapacity not provided, defaults to the Btu/hr equivalent of the heat pump COP multiplied by 0.5 kW for 240V HPWHs, 0.422 kW for 120V HPWHs with a dedicated circuit, or 0.357 for all other 120V HPWHs.
+ .. [#] If BackupHeatingCapacity not provided, defaults to 15355 (4.5 kW) for 240V HPWHs or 0 (no backup elements) for 120V HPWHs.
.. [#] HPWHOperatingMode choices are "hybrid/auto" or "heat pump only".
.. [#] The heat pump water heater operating mode can alternatively be defined using :ref:`schedules_detailed`.
+ .. [#] HPWHVoltage choices are "240V", "120V", "120V dedicated circuit", or "120V shared circuit".
+ .. [#] OpenStudio-HPXML currently only supports ExhaustAirTermination="outside" for heat pump water heaters located in conditioned space.
+ Any other combination of ExhaustAirTermination value and water heater location will be ignored w/ a warning.
.. [#] UsageBin choices are "very small", "low", "medium", or "high".
.. [#] UsageBin/FirstHourRating are only used for water heaters that use UniformEnergyFactor.
If neither UsageBin nor FirstHourRating provided, UsageBin defaults to "medium".
If FirstHourRating provided and UsageBin not provided, UsageBin is determined based on the FirstHourRating value.
.. [#] The water heater setpoint can alternatively be defined using :ref:`schedules_detailed`.
+ .. [#] If HasMixingValve not provided, defaults to true for a 120V HPWH and otherwise false.
+ .. [#] If MixingValveSetpoint not provided and HasMixingValve=true, defaults to the lesser of 125 deg-F and HotWaterTemperature.
.. [#] Additional desuperheater inputs are described in :ref:`water_heater_desuperheater`.
.. [#] NumberofBedroomsServed only required if IsSharedSystem is true.
Tank losses will be apportioned to the dwelling unit using its number of bedrooms divided by the total number of bedrooms served by the water heating system per `ANSI/RESNET/ICC 301-2022 `_.
@@ -4313,7 +4326,9 @@ Each combination boiler w/ storage tank (sometimes referred to as an indirect wa
``FractionDHWLoadServed`` double frac >= 0, <= 1 [#]_ Yes Fraction of hot water load served [#]_
``WaterHeaterInsulation/Jacket/JacketRValue`` double F-ft2-hr/Btu >= 0 No 0 R-value of additional storage tank insulation wrap
``StandbyLoss[Units="F/hr"]/Value`` double F/hr > 0 No See [#]_ Storage tank standby losses
- ``HotWaterTemperature`` double F > 0 No 125 Water heater setpoint [#]_
+ ``HotWaterTemperature`` double F >= 105 No 125 Water heater setpoint [#]_
+ ``HasMixingValve`` boolean No false Presence of a water heater mixing value?
+ ``MixingValveSetpoint`` double F >= 105, <= HotWaterTemperature No See [#]_ Temperature setpoint for the mixing valve
``RelatedHVACSystem`` idref See [#]_ Yes ID of boiler
``extension/NumberofBedroomsServed`` integer > NumberofBedrooms See [#]_ Number of bedrooms served directly or indirectly
============================================= ======= ============ ====================================== ============ ======== ==================================================
@@ -4332,6 +4347,7 @@ Each combination boiler w/ storage tank (sometimes referred to as an indirect wa
Additional hot water load from clothes washers/dishwashers will be automatically assigned to the appropriate water heater(s).
.. [#] If StandbyLoss not provided, defaults based on a regression analysis of `AHRI Directory of Certified Product Performance `_.
.. [#] The water heater setpoint can alternatively be defined using :ref:`schedules_detailed`.
+ .. [#] If MixingValveSetpoint not provided and HasMixingValve=true, defaults to the lesser of 125 deg-F and HotWaterTemperature.
.. [#] RelatedHVACSystem must reference a ``HeatingSystem`` (Boiler).
.. [#] NumberofBedroomsServed only required if IsSharedSystem is true.
Tank losses will be apportioned to the dwelling unit using its number of bedrooms divided by the total number of bedrooms served by the water heating system per `ANSI/RESNET/ICC 301-2022 `_.
@@ -4352,7 +4368,9 @@ Each combination boiler w/ tankless coil is entered as a ``/HPXML/Building/Build
``Location`` string See [#]_ No See [#]_ Water heater location
``IsSharedSystem`` boolean No false Whether it serves multiple dwelling units or shared laundry room
``FractionDHWLoadServed`` double frac >= 0, <= 1 [#]_ Yes Fraction of hot water load served [#]_
- ``HotWaterTemperature`` double F > 0 No 125 Water heater setpoint [#]_
+ ``HotWaterTemperature`` double F >= 105 No 125 Water heater setpoint [#]_
+ ``HasMixingValve`` boolean No false Presence of a water heater mixing value?
+ ``MixingValveSetpoint`` double F >= 105, <= HotWaterTemperature No See [#]_ Temperature setpoint for the mixing valve
``RelatedHVACSystem`` idref See [#]_ Yes ID of boiler
``extension/NumberofBedroomsServed`` integer > NumberofBedrooms See [#]_ Number of bedrooms served directly or indirectly
==================================== ======= ===== ======================================= ============ ======== ==================================================
@@ -4369,6 +4387,7 @@ Each combination boiler w/ tankless coil is entered as a ``/HPXML/Building/Build
.. [#] FractionDHWLoadServed represents only the fraction of the hot water load associated with the hot water **fixtures**.
Additional hot water load from clothes washers/dishwashers will be automatically assigned to the appropriate water heater(s).
.. [#] The water heater setpoint can alternatively be defined using :ref:`schedules_detailed`.
+ .. [#] If MixingValveSetpoint not provided and HasMixingValve=true, defaults to the lesser of 125 deg-F and HotWaterTemperature.
.. [#] RelatedHVACSystem must reference a ``HeatingSystem`` (Boiler).
.. [#] NumberofBedroomsServed only required if IsSharedSystem is true.
Each dwelling unit w/zero bedrooms should be counted as 1 bedroom -- e.g., a value of 3 should be entered for a shared system serving 3 studio (zero bedroom) apartments.
@@ -4813,7 +4832,7 @@ Individual branch circuits entered in ``BranchCircuits/BranchCircuit``.
\- ``HeatPump[HeatPumpFuel="electricity"]``: 240
- \- ``WaterHeatingSystem[FuelType="electricity"]``: 240
+ \- ``WaterHeatingSystem[FuelType="electricity"]``: 240, or 120 if a heat pump water heater with HPWHVoltage=120V
\- ``ClothesDryer[FuelType="electricity"]``: 240
diff --git a/tasks.rb b/tasks.rb
index a022d49334..2599b39962 100644
--- a/tasks.rb
+++ b/tasks.rb
@@ -2373,6 +2373,13 @@ def apply_hpxml_modification_sample_files(hpxml_path, hpxml)
elsif ['base-dhw-tank-gas-fhr.xml'].include? hpxml_file
hpxml_bldg.water_heating_systems[0].first_hour_rating = 56.0
hpxml_bldg.water_heating_systems[0].usage_bin = nil
+ elsif ['base-dhw-tank-heat-pump-120v.xml'].include? hpxml_file
+ hpxml_bldg.water_heating_systems[0].hpwh_voltage = HPXML::HPWHVoltage120
+ elsif ['base-dhw-tank-heat-pump-120v-dedicated-circuit.xml'].include? hpxml_file
+ hpxml_bldg.water_heating_systems[0].hpwh_voltage = HPXML::HPWHVoltage120Dedicated
+ elsif ['base-dhw-setpoint-temperature-mixing-valve.xml'].include? hpxml_file
+ hpxml_bldg.water_heating_systems[0].has_mixing_valve = true
+ hpxml_bldg.water_heating_systems[0].mixing_valve_setpoint = 120
elsif ['base-dhw-tank-heat-pump-confined-space.xml'].include? hpxml_file
hpxml_bldg.water_heating_systems[0].hpwh_confined_space_without_mitigation = true
hpxml_bldg.water_heating_systems[0].hpwh_containment_volume = 453
diff --git a/workflow/hpxml_inputs.json b/workflow/hpxml_inputs.json
index 533999719b..c4034b7fae 100644
--- a/workflow/hpxml_inputs.json
+++ b/workflow/hpxml_inputs.json
@@ -952,6 +952,12 @@
"parent_hpxml": "sample_files/base.xml",
"dhw_water_heater": "Electricity, Heat Pump, UEF 3.50"
},
+ "sample_files/base-dhw-tank-heat-pump-120v.xml": {
+ "parent_hpxml": "sample_files/base-dhw-tank-heat-pump.xml"
+ },
+ "sample_files/base-dhw-tank-heat-pump-120v-dedicated-circuit.xml": {
+ "parent_hpxml": "sample_files/base-dhw-tank-heat-pump.xml"
+ },
"sample_files/base-dhw-tank-heat-pump-confined-space.xml": {
"parent_hpxml": "sample_files/base-dhw-tank-heat-pump.xml"
},
@@ -1041,6 +1047,9 @@
"parent_hpxml": "sample_files/base.xml",
"dhw_water_heater": "Detailed Example: Electricity, Tank, UEF 0.94, 135F"
},
+ "sample_files/base-dhw-setpoint-temperature-mixing-valve.xml": {
+ "parent_hpxml": "sample_files/base-dhw-setpoint-temperature.xml"
+ },
"sample_files/base-detailed-electric-panel.xml": {
"parent_hpxml": "sample_files/base.xml",
"geometry_unit_conditioned_floor_area": "1228",
diff --git a/workflow/sample_files/base-dhw-setpoint-temperature-mixing-valve.xml b/workflow/sample_files/base-dhw-setpoint-temperature-mixing-valve.xml
new file mode 100644
index 0000000000..b4e9a22bf7
--- /dev/null
+++ b/workflow/sample_files/base-dhw-setpoint-temperature-mixing-valve.xml
@@ -0,0 +1,519 @@
+
+
+
+ HPXML
+ tasks.rb
+ 2000-01-01T00:00:00-07:00
+ create
+
+
+
+
+
+ Default
+
+
+
+
+
+
+
+
+
+ CO
+
+
+
+ proposed workscope
+
+
+
+
+ stand-alone
+ no units above or below
+ 180
+
+ electricity
+ natural gas
+
+
+
+ single-family detached
+ 2.0
+ 1.0
+ 8.0
+ 3
+ 2
+ 2700.0
+ 21600.0
+
+
+
+
+ 2006
+ 5B
+
+
+
+ USA_CO_Denver.Intl.AP.725650_TMY3
+
+ USA_CO_Denver.Intl.AP.725650_TMY3.epw
+
+
+
+
+
+
+
+ 50.0
+
+ ACH
+ 3.0
+
+
+
+
+
+
+
+
+ false
+
+
+
+
+
+
+
+
+
+
+
+
+ true
+
+
+
+
+
+
+
+
+
+
+ attic - unvented
+ 1509.3
+ asphalt or fiberglass shingles
+ light
+ 6.0
+
+
+ 2.3
+
+
+
+
+
+
+ outside
+ basement - conditioned
+ 115.6
+ wood siding
+ medium
+
+
+ 13.9
+
+
+
+
+
+
+ outside
+ conditioned space
+
+
+
+ 1200.0
+ wood siding
+ medium
+
+
+ 22.7
+
+
+
+
+ outside
+ attic - unvented
+ gable
+
+
+
+ 225.0
+ wood siding
+ medium
+
+
+ 4.0
+
+
+
+
+
+
+ ground
+ basement - conditioned
+ solid concrete
+ 8.0
+ 1200.0
+ 7.0
+
+
+
+ continuous - exterior
+ 10.0
+
+
+ continuous - interior
+ 0.0
+
+
+
+
+
+
+
+ attic - unvented
+ conditioned space
+ ceiling
+
+
+
+ 1350.0
+
+
+ 39.6
+
+
+
+
+
+
+ basement - conditioned
+ 1350.0
+ 150.0
+
+
+
+ 0.0
+ 0.0
+
+
+
+
+
+ 0.0
+ 0.0
+
+
+
+ 0.0
+ 0.0
+
+
+
+
+
+
+ 108.0
+ 0
+ 0.35
+ 0.44
+
+
+ light curtains
+
+ 0.67
+
+
+
+
+ 72.0
+ 90
+ 0.35
+ 0.44
+
+
+ light curtains
+
+ 0.67
+
+
+
+
+ 108.0
+ 180
+ 0.35
+ 0.44
+
+
+ light curtains
+
+ 0.67
+
+
+
+
+ 72.0
+ 270
+ 0.35
+ 0.44
+
+
+ light curtains
+
+ 0.67
+
+
+
+
+
+
+
+ 40.0
+ 180
+ 4.4
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ natural gas
+ 35000.0
+
+ AFUE
+ 0.92
+
+ 1.0
+
+
+
+
+ central air conditioner
+ electricity
+ 24000.0
+ single stage
+ 1.0
+
+ SEER2
+ 13.4
+
+
+
+
+
+ 68.0
+ 78.0
+
+
+
+
+
+ regular velocity
+
+ supply
+
+ CFM25
+ 81.0
+ to outside
+
+
+
+ return
+
+ CFM25
+ 27.0
+ to outside
+
+
+
+
+ supply
+ 4.0
+ attic - unvented
+ 0.75
+
+
+
+ return
+ 4.0
+ attic - unvented
+ 0.75
+
+
+
+ supply
+ 0.0
+ conditioned space
+ 0.25
+
+
+
+ return
+ 0.0
+ conditioned space
+ 0.25
+
+
+
+ 2700.0
+
+
+
+
+
+ electricity
+ storage water heater
+ conditioned space
+ 1.0
+ 0.94
+ 135.0
+ true
+ 120.0
+
+
+
+
+
+
+
+ 0.0
+
+
+
+
+ shower head
+ false
+
+
+
+ faucet
+ false
+
+
+
+
+
+
+ 1.21
+ 380.0
+ 0.12
+ 1.09
+ 27.0
+ 6.0
+ 3.2
+
+
+
+ electricity
+ conventional
+ 3.73
+
+
+
+ 307.0
+ 12
+ 0.12
+ 1.09
+ 22.32
+ 4.0
+
+
+
+ 650.0
+
+
+
+ electricity
+ false
+
+
+
+ false
+
+
+
+
+
+ interior
+ 0.4
+
+
+
+
+
+
+ interior
+ 0.1
+
+
+
+
+
+
+ interior
+ 0.25
+
+
+
+
+
+
+ exterior
+ 0.4
+
+
+
+
+
+
+ exterior
+ 0.1
+
+
+
+
+
+
+ exterior
+ 0.25
+
+
+
+
+
+
+
+
+ TV other
+
+
+
+ other
+
+
+
+
+
\ No newline at end of file
diff --git a/workflow/sample_files/base-dhw-tank-heat-pump-120v-dedicated-circuit.xml b/workflow/sample_files/base-dhw-tank-heat-pump-120v-dedicated-circuit.xml
new file mode 100644
index 0000000000..2be1d31e5e
--- /dev/null
+++ b/workflow/sample_files/base-dhw-tank-heat-pump-120v-dedicated-circuit.xml
@@ -0,0 +1,517 @@
+
+
+
+ HPXML
+ tasks.rb
+ 2000-01-01T00:00:00-07:00
+ create
+
+
+
+
+
+ Default
+
+
+
+
+
+
+
+
+
+ CO
+
+
+
+ proposed workscope
+
+
+
+
+ stand-alone
+ no units above or below
+ 180
+
+ electricity
+ natural gas
+
+
+
+ single-family detached
+ 2.0
+ 1.0
+ 8.0
+ 3
+ 2
+ 2700.0
+ 21600.0
+
+
+
+
+ 2006
+ 5B
+
+
+
+ USA_CO_Denver.Intl.AP.725650_TMY3
+
+ USA_CO_Denver.Intl.AP.725650_TMY3.epw
+
+
+
+
+
+
+
+ 50.0
+
+ ACH
+ 3.0
+
+
+
+
+
+
+
+
+ false
+
+
+
+
+
+
+
+
+
+
+
+
+ true
+
+
+
+
+
+
+
+
+
+
+ attic - unvented
+ 1509.3
+ asphalt or fiberglass shingles
+ light
+ 6.0
+
+
+ 2.3
+
+
+
+
+
+
+ outside
+ basement - conditioned
+ 115.6
+ wood siding
+ medium
+
+
+ 13.9
+
+
+
+
+
+
+ outside
+ conditioned space
+
+
+
+ 1200.0
+ wood siding
+ medium
+
+
+ 22.7
+
+
+
+
+ outside
+ attic - unvented
+ gable
+
+
+
+ 225.0
+ wood siding
+ medium
+
+
+ 4.0
+
+
+
+
+
+
+ ground
+ basement - conditioned
+ solid concrete
+ 8.0
+ 1200.0
+ 7.0
+
+
+
+ continuous - exterior
+ 10.0
+
+
+ continuous - interior
+ 0.0
+
+
+
+
+
+
+
+ attic - unvented
+ conditioned space
+ ceiling
+
+
+
+ 1350.0
+
+
+ 39.6
+
+
+
+
+
+
+ basement - conditioned
+ 1350.0
+ 150.0
+
+
+
+ 0.0
+ 0.0
+
+
+
+
+
+ 0.0
+ 0.0
+
+
+
+ 0.0
+ 0.0
+
+
+
+
+
+
+ 108.0
+ 0
+ 0.35
+ 0.44
+
+
+ light curtains
+
+ 0.67
+
+
+
+
+ 72.0
+ 90
+ 0.35
+ 0.44
+
+
+ light curtains
+
+ 0.67
+
+
+
+
+ 108.0
+ 180
+ 0.35
+ 0.44
+
+
+ light curtains
+
+ 0.67
+
+
+
+
+ 72.0
+ 270
+ 0.35
+ 0.44
+
+
+ light curtains
+
+ 0.67
+
+
+
+
+
+
+
+ 40.0
+ 180
+ 4.4
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ natural gas
+ 35000.0
+
+ AFUE
+ 0.92
+
+ 1.0
+
+
+
+
+ central air conditioner
+ electricity
+ 24000.0
+ single stage
+ 1.0
+
+ SEER2
+ 13.4
+
+
+
+
+
+ 68.0
+ 78.0
+
+
+
+
+
+ regular velocity
+
+ supply
+
+ CFM25
+ 81.0
+ to outside
+
+
+
+ return
+
+ CFM25
+ 27.0
+ to outside
+
+
+
+
+ supply
+ 4.0
+ attic - unvented
+ 0.75
+
+
+
+ return
+ 4.0
+ attic - unvented
+ 0.75
+
+
+
+ supply
+ 0.0
+ conditioned space
+ 0.25
+
+
+
+ return
+ 0.0
+ conditioned space
+ 0.25
+
+
+
+ 2700.0
+
+
+
+
+
+ electricity
+ heat pump water heater
+ conditioned space
+ 1.0
+ 3.5
+ 120V dedicated circuit
+
+
+
+
+
+
+
+ 0.0
+
+
+
+
+ shower head
+ false
+
+
+
+ faucet
+ false
+
+
+
+
+
+
+ 1.21
+ 380.0
+ 0.12
+ 1.09
+ 27.0
+ 6.0
+ 3.2
+
+
+
+ electricity
+ conventional
+ 3.73
+
+
+
+ 307.0
+ 12
+ 0.12
+ 1.09
+ 22.32
+ 4.0
+
+
+
+ 650.0
+
+
+
+ electricity
+ false
+
+
+
+ false
+
+
+
+
+
+ interior
+ 0.4
+
+
+
+
+
+
+ interior
+ 0.1
+
+
+
+
+
+
+ interior
+ 0.25
+
+
+
+
+
+
+ exterior
+ 0.4
+
+
+
+
+
+
+ exterior
+ 0.1
+
+
+
+
+
+
+ exterior
+ 0.25
+
+
+
+
+
+
+
+
+ TV other
+
+
+
+ other
+
+
+
+
+
\ No newline at end of file
diff --git a/workflow/sample_files/base-dhw-tank-heat-pump-120v.xml b/workflow/sample_files/base-dhw-tank-heat-pump-120v.xml
new file mode 100644
index 0000000000..4fa1092ff4
--- /dev/null
+++ b/workflow/sample_files/base-dhw-tank-heat-pump-120v.xml
@@ -0,0 +1,517 @@
+
+
+
+ HPXML
+ tasks.rb
+ 2000-01-01T00:00:00-07:00
+ create
+
+
+
+
+
+ Default
+
+
+
+
+
+
+
+
+
+ CO
+
+
+
+ proposed workscope
+
+
+
+
+ stand-alone
+ no units above or below
+ 180
+
+ electricity
+ natural gas
+
+
+
+ single-family detached
+ 2.0
+ 1.0
+ 8.0
+ 3
+ 2
+ 2700.0
+ 21600.0
+
+
+
+
+ 2006
+ 5B
+
+
+
+ USA_CO_Denver.Intl.AP.725650_TMY3
+
+ USA_CO_Denver.Intl.AP.725650_TMY3.epw
+
+
+
+
+
+
+
+ 50.0
+
+ ACH
+ 3.0
+
+
+
+
+
+
+
+
+ false
+
+
+
+
+
+
+
+
+
+
+
+
+ true
+
+
+
+
+
+
+
+
+
+
+ attic - unvented
+ 1509.3
+ asphalt or fiberglass shingles
+ light
+ 6.0
+
+
+ 2.3
+
+
+
+
+
+
+ outside
+ basement - conditioned
+ 115.6
+ wood siding
+ medium
+
+
+ 13.9
+
+
+
+
+
+
+ outside
+ conditioned space
+
+
+
+ 1200.0
+ wood siding
+ medium
+
+
+ 22.7
+
+
+
+
+ outside
+ attic - unvented
+ gable
+
+
+
+ 225.0
+ wood siding
+ medium
+
+
+ 4.0
+
+
+
+
+
+
+ ground
+ basement - conditioned
+ solid concrete
+ 8.0
+ 1200.0
+ 7.0
+
+
+
+ continuous - exterior
+ 10.0
+
+
+ continuous - interior
+ 0.0
+
+
+
+
+
+
+
+ attic - unvented
+ conditioned space
+ ceiling
+
+
+
+ 1350.0
+
+
+ 39.6
+
+
+
+
+
+
+ basement - conditioned
+ 1350.0
+ 150.0
+
+
+
+ 0.0
+ 0.0
+
+
+
+
+
+ 0.0
+ 0.0
+
+
+
+ 0.0
+ 0.0
+
+
+
+
+
+
+ 108.0
+ 0
+ 0.35
+ 0.44
+
+
+ light curtains
+
+ 0.67
+
+
+
+
+ 72.0
+ 90
+ 0.35
+ 0.44
+
+
+ light curtains
+
+ 0.67
+
+
+
+
+ 108.0
+ 180
+ 0.35
+ 0.44
+
+
+ light curtains
+
+ 0.67
+
+
+
+
+ 72.0
+ 270
+ 0.35
+ 0.44
+
+
+ light curtains
+
+ 0.67
+
+
+
+
+
+
+
+ 40.0
+ 180
+ 4.4
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ natural gas
+ 35000.0
+
+ AFUE
+ 0.92
+
+ 1.0
+
+
+
+
+ central air conditioner
+ electricity
+ 24000.0
+ single stage
+ 1.0
+
+ SEER2
+ 13.4
+
+
+
+
+
+ 68.0
+ 78.0
+
+
+
+
+
+ regular velocity
+
+ supply
+
+ CFM25
+ 81.0
+ to outside
+
+
+
+ return
+
+ CFM25
+ 27.0
+ to outside
+
+
+
+
+ supply
+ 4.0
+ attic - unvented
+ 0.75
+
+
+
+ return
+ 4.0
+ attic - unvented
+ 0.75
+
+
+
+ supply
+ 0.0
+ conditioned space
+ 0.25
+
+
+
+ return
+ 0.0
+ conditioned space
+ 0.25
+
+
+
+ 2700.0
+
+
+
+
+
+ electricity
+ heat pump water heater
+ conditioned space
+ 1.0
+ 3.5
+ 120V
+
+
+
+
+
+
+
+ 0.0
+
+
+
+
+ shower head
+ false
+
+
+
+ faucet
+ false
+
+
+
+
+
+
+ 1.21
+ 380.0
+ 0.12
+ 1.09
+ 27.0
+ 6.0
+ 3.2
+
+
+
+ electricity
+ conventional
+ 3.73
+
+
+
+ 307.0
+ 12
+ 0.12
+ 1.09
+ 22.32
+ 4.0
+
+
+
+ 650.0
+
+
+
+ electricity
+ false
+
+
+
+ false
+
+
+
+
+
+ interior
+ 0.4
+
+
+
+
+
+
+ interior
+ 0.1
+
+
+
+
+
+
+ interior
+ 0.25
+
+
+
+
+
+
+ exterior
+ 0.4
+
+
+
+
+
+
+ exterior
+ 0.1
+
+
+
+
+
+
+ exterior
+ 0.25
+
+
+
+
+
+
+
+
+ TV other
+
+
+
+ other
+
+
+
+
+
\ No newline at end of file
diff --git a/workflow/tests/base_results/results_simulations_bills.csv b/workflow/tests/base_results/results_simulations_bills.csv
index 82ce9754b8..e3a10c1ddc 100644
--- a/workflow/tests/base_results/results_simulations_bills.csv
+++ b/workflow/tests/base_results/results_simulations_bills.csv
@@ -107,6 +107,7 @@ base-dhw-recirc-manual.xml,1983.0,144.0,1378.8,0.0,1522.8,144.0,316.2,460.2,0.0,
base-dhw-recirc-nocontrol.xml,2507.75,144.0,1903.55,0.0,2047.55,144.0,316.2,460.2,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
base-dhw-recirc-temperature.xml,2329.08,144.0,1724.88,0.0,1868.88,144.0,316.2,460.2,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
base-dhw-recirc-timer.xml,2507.75,144.0,1903.55,0.0,2047.55,144.0,316.2,460.2,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
+base-dhw-setpoint-temperature-mixing-valve.xml,2046.43,144.0,1443.51,0.0,1587.51,144.0,314.92,458.92,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
base-dhw-setpoint-temperature.xml,2056.45,144.0,1453.53,0.0,1597.53,144.0,314.92,458.92,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
base-dhw-solar-direct-evacuated-tube.xml,1803.18,144.0,1198.98,0.0,1342.98,144.0,316.2,460.2,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
base-dhw-solar-direct-flat-plate.xml,1736.31,144.0,1132.2,0.0,1276.2,144.0,316.11,460.11,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
@@ -121,6 +122,8 @@ base-dhw-tank-gas-ef.xml,1828.35,144.0,1050.23,0.0,1194.23,144.0,490.12,634.12,0
base-dhw-tank-gas-fhr.xml,1822.21,144.0,1048.93,0.0,1192.93,144.0,485.28,629.28,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
base-dhw-tank-gas-outside.xml,1829.38,144.0,1042.1,0.0,1186.1,144.0,499.28,643.28,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
base-dhw-tank-gas.xml,1822.21,144.0,1048.93,0.0,1192.93,144.0,485.28,629.28,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
+base-dhw-tank-heat-pump-120v-dedicated-circuit.xml,1837.86,144.0,1174.72,0.0,1318.72,144.0,375.14,519.14,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
+base-dhw-tank-heat-pump-120v.xml,1815.57,144.0,1145.73,0.0,1289.73,144.0,381.84,525.84,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
base-dhw-tank-heat-pump-capacities.xml,1803.37,144.0,1129.36,0.0,1273.36,144.0,386.01,530.01,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
base-dhw-tank-heat-pump-confined-space.xml,1818.34,144.0,1149.31,0.0,1293.31,144.0,381.03,525.03,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
base-dhw-tank-heat-pump-detailed-schedules.xml,1824.21,144.0,1152.08,0.0,1296.08,144.0,384.13,528.13,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
diff --git a/workflow/tests/base_results/results_simulations_energy.csv b/workflow/tests/base_results/results_simulations_energy.csv
index 8c3ab982e3..0d5d1a5603 100644
--- a/workflow/tests/base_results/results_simulations_energy.csv
+++ b/workflow/tests/base_results/results_simulations_energy.csv
@@ -107,6 +107,7 @@ base-dhw-recirc-manual.xml,70.185,70.185,37.547,37.547,32.638,0.0,0.0,0.0,0.0,0.
base-dhw-recirc-nocontrol.xml,84.475,84.475,51.837,51.837,32.638,0.0,0.0,0.0,0.0,0.0,0.0,1.016,0.0,0.0,5.216,1.204,21.895,1.495,0.0,4.507,0.0,0.334,0.0,0.0,0.0,0.0,2.075,0.0,0.0,0.284,0.347,1.436,1.529,0.0,2.116,8.384,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,32.638,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0
base-dhw-recirc-temperature.xml,79.609,79.609,46.972,46.972,32.638,0.0,0.0,0.0,0.0,0.0,0.0,1.016,0.0,0.0,5.216,1.204,18.274,0.249,0.0,4.507,0.0,0.334,0.0,0.0,0.0,0.0,2.075,0.0,0.0,0.284,0.347,1.436,1.529,0.0,2.116,8.384,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,32.638,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0
base-dhw-recirc-timer.xml,84.475,84.475,51.837,51.837,32.638,0.0,0.0,0.0,0.0,0.0,0.0,1.016,0.0,0.0,5.216,1.204,21.895,1.495,0.0,4.507,0.0,0.334,0.0,0.0,0.0,0.0,2.075,0.0,0.0,0.284,0.347,1.436,1.529,0.0,2.116,8.384,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,32.638,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0
+base-dhw-setpoint-temperature-mixing-valve.xml,71.815,71.815,39.309,39.309,32.506,0.0,0.0,0.0,0.0,0.0,0.0,1.012,0.0,0.0,5.232,1.209,10.846,0.0,0.0,4.507,0.0,0.334,0.0,0.0,0.0,0.0,2.075,0.0,0.0,0.284,0.347,1.436,1.529,0.0,2.116,8.384,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,32.506,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0
base-dhw-setpoint-temperature.xml,72.088,72.088,39.582,39.582,32.506,0.0,0.0,0.0,0.0,0.0,0.0,1.012,0.0,0.0,5.232,1.209,11.118,0.0,0.0,4.507,0.0,0.334,0.0,0.0,0.0,0.0,2.075,0.0,0.0,0.284,0.347,1.436,1.529,0.0,2.116,8.384,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,32.506,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0
base-dhw-solar-direct-evacuated-tube.xml,65.289,65.289,32.65,32.65,32.638,0.0,0.0,0.0,0.0,0.0,0.0,1.016,0.0,0.0,5.218,1.205,3.874,0.0,0.325,4.507,0.0,0.334,0.0,0.0,0.0,0.0,2.075,0.0,0.0,0.284,0.347,1.436,1.529,0.0,2.116,8.384,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,32.638,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0
base-dhw-solar-direct-flat-plate.xml,63.461,63.461,30.832,30.832,32.629,0.0,0.0,0.0,0.0,0.0,0.0,1.016,0.0,0.0,5.234,1.209,2.049,0.0,0.313,4.507,0.0,0.334,0.0,0.0,0.0,0.0,2.075,0.0,0.0,0.284,0.347,1.436,1.529,0.0,2.116,8.384,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,32.629,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0
@@ -121,6 +122,8 @@ base-dhw-tank-gas-ef.xml,79.19,79.19,28.6,28.6,50.591,0.0,0.0,0.0,0.0,0.0,0.0,1.
base-dhw-tank-gas-fhr.xml,78.655,78.655,28.564,28.564,50.091,0.0,0.0,0.0,0.0,0.0,0.0,1.041,0.0,0.0,5.289,1.223,0.0,0.0,0.0,4.507,0.0,0.334,0.0,0.0,0.0,0.0,2.075,0.0,0.0,0.284,0.347,1.436,1.529,0.0,2.116,8.384,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,33.453,0.0,16.638,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0
base-dhw-tank-gas-outside.xml,79.914,79.914,28.378,28.378,51.536,0.0,0.0,0.0,0.0,0.0,0.0,1.039,0.0,0.0,5.144,1.185,0.0,0.0,0.0,4.507,0.0,0.334,0.0,0.0,0.0,0.0,2.073,0.0,0.0,0.284,0.347,1.436,1.529,0.0,2.116,8.384,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,33.385,0.0,18.151,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0
base-dhw-tank-gas.xml,78.655,78.655,28.564,28.564,50.091,0.0,0.0,0.0,0.0,0.0,0.0,1.041,0.0,0.0,5.289,1.223,0.0,0.0,0.0,4.507,0.0,0.334,0.0,0.0,0.0,0.0,2.075,0.0,0.0,0.284,0.347,1.436,1.529,0.0,2.116,8.384,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,33.453,0.0,16.638,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0
+base-dhw-tank-heat-pump-120v-dedicated-circuit.xml,70.712,70.712,31.99,31.99,38.722,0.0,0.0,0.0,0.0,0.0,0.0,1.205,0.0,0.0,4.644,1.052,4.085,0.0,0.0,4.507,0.0,0.334,0.0,0.0,0.0,0.0,2.066,0.0,0.0,0.284,0.347,1.436,1.529,0.0,2.116,8.384,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,38.722,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0
+base-dhw-tank-heat-pump-120v.xml,70.614,70.614,31.2,31.2,39.414,0.0,0.0,0.0,0.0,0.0,0.0,1.227,0.0,0.0,4.589,1.038,3.345,0.0,0.0,4.507,0.0,0.334,0.0,0.0,0.0,0.0,2.065,0.0,0.0,0.284,0.347,1.436,1.529,0.0,2.116,8.384,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,39.414,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0
base-dhw-tank-heat-pump-capacities.xml,70.599,70.599,30.754,30.754,39.844,0.0,0.0,0.0,0.0,0.0,0.0,1.24,0.0,0.0,4.553,1.028,2.931,0.0,0.0,4.507,0.0,0.334,0.0,0.0,0.0,0.0,2.065,0.0,0.0,0.284,0.347,1.436,1.529,0.0,2.116,8.384,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,39.844,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0
base-dhw-tank-heat-pump-confined-space.xml,70.628,70.628,31.298,31.298,39.33,0.0,0.0,0.0,0.0,0.0,0.0,1.224,0.0,0.0,4.607,1.043,3.422,0.0,0.0,4.507,0.0,0.334,0.0,0.0,0.0,0.0,2.065,0.0,0.0,0.284,0.347,1.436,1.529,0.0,2.116,8.384,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,39.33,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0
base-dhw-tank-heat-pump-detailed-schedules.xml,71.023,71.023,31.373,31.373,39.65,0.0,0.0,0.0,0.0,0.0,0.0,1.234,0.0,0.0,4.693,1.06,3.385,0.0,0.0,4.507,0.0,0.334,0.0,0.0,0.0,0.0,2.064,0.0,0.0,0.284,0.347,1.436,1.529,0.0,2.116,8.384,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,39.65,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0
diff --git a/workflow/tests/base_results/results_simulations_hvac.csv b/workflow/tests/base_results/results_simulations_hvac.csv
index b4120122d2..c4c5eb7732 100644
--- a/workflow/tests/base_results/results_simulations_hvac.csv
+++ b/workflow/tests/base_results/results_simulations_hvac.csv
@@ -107,6 +107,7 @@ base-dhw-recirc-manual.xml,6.8,91.76,35000.0,24000.0,0.0,41543.0,17659.0,7963.0,
base-dhw-recirc-nocontrol.xml,6.8,91.76,35000.0,24000.0,0.0,41543.0,17659.0,7963.0,0.0,575.0,6833.0,0.0,0.0,1738.0,2155.0,4620.0,0.0,0.0,27993.0,13311.0,7750.0,0.0,207.0,507.0,0.0,0.0,0.0,2276.0,622.0,0.0,3320.0,0.0,0.0,265.0,126.0,-661.0,0.0,800.0
base-dhw-recirc-temperature.xml,6.8,91.76,35000.0,24000.0,0.0,41543.0,17659.0,7963.0,0.0,575.0,6833.0,0.0,0.0,1738.0,2155.0,4620.0,0.0,0.0,27993.0,13311.0,7750.0,0.0,207.0,507.0,0.0,0.0,0.0,2276.0,622.0,0.0,3320.0,0.0,0.0,265.0,126.0,-661.0,0.0,800.0
base-dhw-recirc-timer.xml,6.8,91.76,35000.0,24000.0,0.0,41543.0,17659.0,7963.0,0.0,575.0,6833.0,0.0,0.0,1738.0,2155.0,4620.0,0.0,0.0,27993.0,13311.0,7750.0,0.0,207.0,507.0,0.0,0.0,0.0,2276.0,622.0,0.0,3320.0,0.0,0.0,265.0,126.0,-661.0,0.0,800.0
+base-dhw-setpoint-temperature-mixing-valve.xml,6.8,91.76,35000.0,24000.0,0.0,41543.0,17659.0,7963.0,0.0,575.0,6833.0,0.0,0.0,1738.0,2155.0,4620.0,0.0,0.0,27993.0,13311.0,7750.0,0.0,207.0,507.0,0.0,0.0,0.0,2276.0,622.0,0.0,3320.0,0.0,0.0,265.0,126.0,-661.0,0.0,800.0
base-dhw-setpoint-temperature.xml,6.8,91.76,35000.0,24000.0,0.0,41543.0,17659.0,7963.0,0.0,575.0,6833.0,0.0,0.0,1738.0,2155.0,4620.0,0.0,0.0,27993.0,13311.0,7750.0,0.0,207.0,507.0,0.0,0.0,0.0,2276.0,622.0,0.0,3320.0,0.0,0.0,265.0,126.0,-661.0,0.0,800.0
base-dhw-solar-direct-evacuated-tube.xml,6.8,91.76,35000.0,24000.0,0.0,41543.0,17659.0,7963.0,0.0,575.0,6833.0,0.0,0.0,1738.0,2155.0,4620.0,0.0,0.0,27993.0,13311.0,7750.0,0.0,207.0,507.0,0.0,0.0,0.0,2276.0,622.0,0.0,3320.0,0.0,0.0,265.0,126.0,-661.0,0.0,800.0
base-dhw-solar-direct-flat-plate.xml,6.8,91.76,35000.0,24000.0,0.0,41543.0,17659.0,7963.0,0.0,575.0,6833.0,0.0,0.0,1738.0,2155.0,4620.0,0.0,0.0,27993.0,13311.0,7750.0,0.0,207.0,507.0,0.0,0.0,0.0,2276.0,622.0,0.0,3320.0,0.0,0.0,265.0,126.0,-661.0,0.0,800.0
@@ -121,6 +122,8 @@ base-dhw-tank-gas-ef.xml,6.8,91.76,35000.0,24000.0,0.0,41543.0,17659.0,7963.0,0.
base-dhw-tank-gas-fhr.xml,6.8,91.76,35000.0,24000.0,0.0,41543.0,17659.0,7963.0,0.0,575.0,6833.0,0.0,0.0,1738.0,2155.0,4620.0,0.0,0.0,27993.0,13311.0,7750.0,0.0,207.0,507.0,0.0,0.0,0.0,2276.0,622.0,0.0,3320.0,0.0,0.0,265.0,126.0,-661.0,0.0,800.0
base-dhw-tank-gas-outside.xml,6.8,91.76,35000.0,24000.0,0.0,41543.0,17659.0,7963.0,0.0,575.0,6833.0,0.0,0.0,1738.0,2155.0,4620.0,0.0,0.0,27993.0,13311.0,7750.0,0.0,207.0,507.0,0.0,0.0,0.0,2276.0,622.0,0.0,3320.0,0.0,0.0,265.0,126.0,-661.0,0.0,800.0
base-dhw-tank-gas.xml,6.8,91.76,35000.0,24000.0,0.0,41543.0,17659.0,7963.0,0.0,575.0,6833.0,0.0,0.0,1738.0,2155.0,4620.0,0.0,0.0,27993.0,13311.0,7750.0,0.0,207.0,507.0,0.0,0.0,0.0,2276.0,622.0,0.0,3320.0,0.0,0.0,265.0,126.0,-661.0,0.0,800.0
+base-dhw-tank-heat-pump-120v-dedicated-circuit.xml,6.8,91.76,35000.0,24000.0,0.0,41543.0,17659.0,7963.0,0.0,575.0,6833.0,0.0,0.0,1738.0,2155.0,4620.0,0.0,0.0,27993.0,13311.0,7750.0,0.0,207.0,507.0,0.0,0.0,0.0,2276.0,622.0,0.0,3320.0,0.0,0.0,265.0,126.0,-661.0,0.0,800.0
+base-dhw-tank-heat-pump-120v.xml,6.8,91.76,35000.0,24000.0,0.0,41543.0,17659.0,7963.0,0.0,575.0,6833.0,0.0,0.0,1738.0,2155.0,4620.0,0.0,0.0,27993.0,13311.0,7750.0,0.0,207.0,507.0,0.0,0.0,0.0,2276.0,622.0,0.0,3320.0,0.0,0.0,265.0,126.0,-661.0,0.0,800.0
base-dhw-tank-heat-pump-capacities.xml,6.8,91.76,35000.0,24000.0,0.0,41543.0,17659.0,7963.0,0.0,575.0,6833.0,0.0,0.0,1738.0,2155.0,4620.0,0.0,0.0,27993.0,13311.0,7750.0,0.0,207.0,507.0,0.0,0.0,0.0,2276.0,622.0,0.0,3320.0,0.0,0.0,265.0,126.0,-661.0,0.0,800.0
base-dhw-tank-heat-pump-confined-space.xml,6.8,91.76,35000.0,24000.0,0.0,41543.0,17659.0,7963.0,0.0,575.0,6833.0,0.0,0.0,1738.0,2155.0,4620.0,0.0,0.0,27993.0,13311.0,7750.0,0.0,207.0,507.0,0.0,0.0,0.0,2276.0,622.0,0.0,3320.0,0.0,0.0,265.0,126.0,-661.0,0.0,800.0
base-dhw-tank-heat-pump-detailed-schedules.xml,6.8,91.76,35000.0,24000.0,0.0,41543.0,17659.0,7963.0,0.0,575.0,6833.0,0.0,0.0,1738.0,2155.0,4620.0,0.0,0.0,27993.0,13311.0,7750.0,0.0,207.0,507.0,0.0,0.0,0.0,2276.0,622.0,0.0,3320.0,0.0,0.0,265.0,126.0,-661.0,0.0,800.0
diff --git a/workflow/tests/base_results/results_simulations_loads.csv b/workflow/tests/base_results/results_simulations_loads.csv
index f72c71ddfb..03abf5bea5 100644
--- a/workflow/tests/base_results/results_simulations_loads.csv
+++ b/workflow/tests/base_results/results_simulations_loads.csv
@@ -107,6 +107,7 @@ base-dhw-recirc-manual.xml,31.045,0.0,20.512,8.416,0.849,0.0,0.0,0.0,3.243,3.875
base-dhw-recirc-nocontrol.xml,31.045,0.0,20.512,8.416,0.849,0.0,0.0,0.0,3.243,3.875,0.882,7.07,0.676,11.539,-12.828,0.0,0.0,0.0,8.304,-0.111,5.504,0.0,0.509,0.0,13.466,-8.481,-2.634,0.0,-0.072,-0.246,-0.022,2.446,0.018,-0.381,12.67,0.0,0.0,0.0,-6.428,-0.107,-0.932,-4.178,-0.085,0.0,8.615,7.311,1.873
base-dhw-recirc-temperature.xml,31.045,0.0,20.512,8.416,0.849,0.0,0.0,0.0,3.243,3.875,0.882,7.07,0.676,11.539,-12.828,0.0,0.0,0.0,8.304,-0.111,5.504,0.0,0.509,0.0,13.466,-8.481,-2.634,0.0,-0.072,-0.246,-0.022,2.446,0.018,-0.381,12.67,0.0,0.0,0.0,-6.428,-0.107,-0.932,-4.178,-0.085,0.0,8.615,7.311,1.873
base-dhw-recirc-timer.xml,31.045,0.0,20.512,8.416,0.849,0.0,0.0,0.0,3.243,3.875,0.882,7.07,0.676,11.539,-12.828,0.0,0.0,0.0,8.304,-0.111,5.504,0.0,0.509,0.0,13.466,-8.481,-2.634,0.0,-0.072,-0.246,-0.022,2.446,0.018,-0.381,12.67,0.0,0.0,0.0,-6.428,-0.107,-0.932,-4.178,-0.085,0.0,8.615,7.311,1.873
+base-dhw-setpoint-temperature-mixing-valve.xml,30.919,0.0,20.587,9.827,1.01,0.0,0.0,0.0,3.243,3.874,0.882,7.068,0.676,11.538,-12.813,0.0,0.0,0.0,8.305,-0.113,5.502,0.0,0.509,0.0,13.418,-8.564,-2.633,0.0,-0.076,-0.249,-0.022,2.44,0.018,-0.386,12.685,0.0,0.0,0.0,-6.433,-0.109,-0.935,-4.189,-0.085,0.0,8.638,7.389,1.874
base-dhw-setpoint-temperature.xml,30.919,0.0,20.586,10.098,1.01,0.0,0.0,0.0,3.243,3.874,0.882,7.068,0.676,11.538,-12.813,0.0,0.0,0.0,8.305,-0.113,5.502,0.0,0.509,0.0,13.418,-8.564,-2.633,0.0,-0.076,-0.249,-0.022,2.44,0.018,-0.386,12.685,0.0,0.0,0.0,-6.433,-0.109,-0.935,-4.189,-0.085,0.0,8.638,7.389,1.874
base-dhw-solar-direct-evacuated-tube.xml,31.045,0.0,20.521,9.926,0.856,0.0,6.91,0.0,3.243,3.875,0.882,7.07,0.676,11.539,-12.828,0.0,0.0,0.0,8.304,-0.111,5.504,0.0,0.509,0.0,13.466,-8.481,-2.634,0.0,-0.072,-0.246,-0.022,2.446,0.018,-0.381,12.67,0.0,0.0,0.0,-6.428,-0.107,-0.932,-4.178,-0.085,0.0,8.618,7.319,1.873
base-dhw-solar-direct-flat-plate.xml,31.036,0.0,20.598,10.011,0.933,0.0,8.897,0.0,3.243,3.876,0.882,7.07,0.676,11.54,-12.828,0.0,0.0,0.0,8.305,-0.111,5.504,0.0,0.509,0.0,13.463,-8.488,-2.634,0.0,-0.073,-0.247,-0.022,2.445,0.018,-0.382,12.67,0.0,0.0,0.0,-6.43,-0.107,-0.932,-4.185,-0.085,0.0,8.641,7.388,1.873
@@ -121,6 +122,8 @@ base-dhw-tank-gas-ef.xml,31.463,0.0,21.007,9.917,3.592,0.0,0.0,0.0,3.236,3.875,0
base-dhw-tank-gas-fhr.xml,31.82,0.0,20.828,9.917,2.944,0.0,0.0,0.0,3.234,3.879,0.883,7.064,0.677,11.559,-12.828,0.0,0.0,0.0,8.291,-0.119,6.629,0.0,0.509,0.0,13.773,-9.123,-2.636,0.0,-0.073,-0.243,-0.02,2.441,0.02,-0.362,12.67,0.0,0.0,0.0,-6.443,-0.115,-1.154,-4.177,-0.084,0.0,8.723,7.748,1.871
base-dhw-tank-gas-outside.xml,31.756,0.0,20.16,9.917,4.114,0.0,0.0,0.0,3.239,3.882,0.884,7.062,0.677,11.555,-12.874,0.0,0.0,0.0,8.298,-0.115,5.517,0.0,0.51,0.0,13.739,-8.01,-2.64,0.0,-0.052,-0.232,-0.018,2.46,0.021,-0.342,12.623,0.0,0.0,0.0,-6.407,-0.11,-0.916,-4.12,-0.083,0.0,8.508,6.932,1.867
base-dhw-tank-gas.xml,31.82,0.0,20.828,9.917,2.944,0.0,0.0,0.0,3.234,3.879,0.883,7.064,0.677,11.559,-12.828,0.0,0.0,0.0,8.291,-0.119,6.629,0.0,0.509,0.0,13.773,-9.123,-2.636,0.0,-0.073,-0.243,-0.02,2.441,0.02,-0.362,12.67,0.0,0.0,0.0,-6.443,-0.115,-1.154,-4.177,-0.084,0.0,8.723,7.748,1.871
+base-dhw-tank-heat-pump-120v-dedicated-circuit.xml,36.827,0.0,17.888,9.917,0.0,0.0,0.0,0.0,3.208,3.939,0.898,7.021,0.687,11.697,-13.288,0.0,0.0,0.0,8.317,-0.129,5.628,0.0,0.517,0.0,15.615,-4.623,-2.71,0.0,0.082,-0.127,0.008,2.561,0.044,-0.039,12.21,0.0,0.0,0.0,-6.192,-0.125,-0.794,-3.769,-0.068,0.0,7.775,4.526,1.797
+base-dhw-tank-heat-pump-120v.xml,37.483,0.0,17.642,9.917,0.0,0.0,0.0,0.0,3.201,3.942,0.899,7.02,0.687,11.695,-13.324,0.0,0.0,0.0,8.319,-0.124,5.635,0.0,0.517,0.0,15.857,-4.174,-2.714,0.0,0.095,-0.119,0.01,2.574,0.045,-0.025,12.174,0.0,0.0,0.0,-6.17,-0.12,-0.788,-3.734,-0.068,0.0,7.693,4.291,1.793
base-dhw-tank-heat-pump-capacities.xml,37.902,0.0,17.498,9.964,0.0,0.0,0.0,0.0,3.191,3.94,0.899,7.008,0.687,11.701,-13.332,0.0,0.0,0.0,8.332,-0.134,5.641,0.0,0.517,0.0,15.984,-3.856,-2.72,0.0,0.094,-0.118,0.01,2.569,0.046,-0.011,12.166,0.0,0.0,0.0,-6.147,-0.13,-0.783,-3.731,-0.067,0.0,7.637,4.161,1.787
base-dhw-tank-heat-pump-confined-space.xml,37.403,0.0,17.744,9.976,1.439,0.0,0.0,0.0,3.205,3.944,0.9,7.012,0.689,11.704,-13.324,0.0,0.0,0.0,8.314,-0.132,5.639,0.0,0.517,0.0,15.817,-4.244,-2.712,0.0,0.093,-0.118,0.01,2.563,0.046,-0.019,12.173,0.0,0.0,0.0,-6.179,-0.128,-0.784,-3.744,-0.068,0.0,7.724,4.362,1.795
base-dhw-tank-heat-pump-detailed-schedules.xml,37.716,0.0,18.016,10.081,1.854,0.0,0.0,0.0,3.188,3.934,0.902,6.941,0.696,11.784,-13.194,0.0,0.0,0.0,8.248,-0.234,5.655,0.0,0.516,0.0,15.979,-4.02,-2.704,0.0,0.076,-0.122,0.014,2.496,0.055,0.079,12.303,0.0,0.0,0.0,-6.22,-0.23,-0.762,-3.631,-0.07,0.0,7.861,4.356,1.803
diff --git a/workflow/tests/base_results/results_simulations_misc.csv b/workflow/tests/base_results/results_simulations_misc.csv
index 8b39f82681..4750497ad3 100644
--- a/workflow/tests/base_results/results_simulations_misc.csv
+++ b/workflow/tests/base_results/results_simulations_misc.csv
@@ -107,6 +107,7 @@ base-dhw-recirc-manual.xml,0.0,87.0,0.0,1286.4,890.5,11468.6,1281.2,2248.1,3763.
base-dhw-recirc-nocontrol.xml,0.0,87.0,0.0,1286.4,890.5,11468.6,1281.2,3108.4,4386.6,4386.6,3108.4,4386.6,4386.6,33304.0,23005.0,0.0
base-dhw-recirc-temperature.xml,0.0,87.0,0.0,1286.4,890.5,11468.6,1281.2,2754.8,4179.7,4179.7,2754.8,4179.7,4179.7,33304.0,23005.0,0.0
base-dhw-recirc-timer.xml,0.0,87.0,0.0,1286.4,890.5,11468.6,1281.2,3108.4,4386.6,4386.6,3108.4,4386.6,4386.6,33304.0,23005.0,0.0
+base-dhw-setpoint-temperature-mixing-valve.xml,0.0,90.0,0.0,1035.3,716.6,9980.5,3430.8,2340.6,3775.7,3775.7,2340.6,3775.7,3775.7,33273.0,23006.0,0.0
base-dhw-setpoint-temperature.xml,0.0,90.0,0.0,1286.4,890.5,9980.5,3430.8,2315.6,3887.6,3887.6,2315.6,3887.6,3887.6,33275.0,23006.0,0.0
base-dhw-solar-direct-evacuated-tube.xml,0.0,88.0,0.0,1286.3,890.4,11388.2,3914.7,2337.6,3383.6,3383.6,2337.6,3383.6,3383.6,33304.0,23005.0,0.0
base-dhw-solar-direct-flat-plate.xml,0.0,90.0,0.0,1286.0,890.2,10691.6,3675.2,2200.1,3383.6,3383.6,2200.1,3383.6,3383.6,33303.0,23006.0,0.0
@@ -121,6 +122,8 @@ base-dhw-tank-gas-ef.xml,0.0,101.0,0.0,1286.4,890.5,11468.9,3942.4,1482.2,3351.7
base-dhw-tank-gas-fhr.xml,0.0,96.0,0.0,1286.4,890.5,11468.8,3942.4,1483.0,3351.7,3351.7,1483.0,3351.7,3351.7,33901.0,23012.0,0.0
base-dhw-tank-gas-outside.xml,0.0,81.0,0.0,1286.4,890.5,11468.6,3942.3,1479.2,3351.6,3351.6,1479.2,3351.6,3351.6,33478.0,23000.0,0.0
base-dhw-tank-gas.xml,0.0,96.0,0.0,1286.4,890.5,11468.8,3942.4,1483.0,3351.7,3351.7,1483.0,3351.7,3351.7,33901.0,23012.0,0.0
+base-dhw-tank-heat-pump-120v-dedicated-circuit.xml,0.0,51.0,0.0,1129.9,781.6,10094.8,3470.1,1960.0,3730.9,3730.9,1960.0,3730.9,3730.9,33379.0,22747.0,0.0
+base-dhw-tank-heat-pump-120v.xml,0.0,50.0,0.0,1129.8,781.7,10094.4,3469.9,1871.9,3704.8,3704.8,1871.9,3704.8,3704.8,33824.0,22738.0,0.0
base-dhw-tank-heat-pump-capacities.xml,0.0,59.0,0.0,1286.4,890.5,11076.4,3807.5,1716.0,3353.3,3353.3,1716.0,3353.3,3353.3,32954.0,22790.0,0.0
base-dhw-tank-heat-pump-confined-space.xml,0.0,54.0,0.0,1286.4,890.5,10972.3,3771.7,1973.3,3750.6,3750.6,1973.3,3750.6,3750.6,35754.0,23036.0,0.0
base-dhw-tank-heat-pump-detailed-schedules.xml,0.0,64.0,0.0,1286.4,890.5,10054.2,3456.1,1839.6,3608.9,3608.9,1839.6,3608.9,3608.9,36443.0,22997.0,0.0
diff --git a/workflow/tests/base_results/results_simulations_panel.csv b/workflow/tests/base_results/results_simulations_panel.csv
index 357adcc5fc..28b9447b97 100644
--- a/workflow/tests/base_results/results_simulations_panel.csv
+++ b/workflow/tests/base_results/results_simulations_panel.csv
@@ -107,6 +107,7 @@ base-dhw-recirc-manual.xml,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0
base-dhw-recirc-nocontrol.xml,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0
base-dhw-recirc-temperature.xml,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0
base-dhw-recirc-timer.xml,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0
+base-dhw-setpoint-temperature-mixing-valve.xml,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0
base-dhw-setpoint-temperature.xml,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0
base-dhw-solar-direct-evacuated-tube.xml,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0
base-dhw-solar-direct-flat-plate.xml,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0
@@ -121,6 +122,8 @@ base-dhw-tank-gas-ef.xml,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0
base-dhw-tank-gas-fhr.xml,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0
base-dhw-tank-gas-outside.xml,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0
base-dhw-tank-gas.xml,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0
+base-dhw-tank-heat-pump-120v-dedicated-circuit.xml,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0
+base-dhw-tank-heat-pump-120v.xml,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0
base-dhw-tank-heat-pump-capacities.xml,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0
base-dhw-tank-heat-pump-confined-space.xml,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0
base-dhw-tank-heat-pump-detailed-schedules.xml,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0
diff --git a/workflow/tests/util.rb b/workflow/tests/util.rb
index e2affbd2fd..68a0be04cc 100644
--- a/workflow/tests/util.rb
+++ b/workflow/tests/util.rb
@@ -351,6 +351,9 @@ def _verify_outputs(rundir, hpxml_path, results, hpxml, unit_multiplier)
next if message.include?('setupIHGOutputs: Output variables=Space Other Equipment') && message.include?('are not available')
next if message.include? 'Multiple speed fan will be applied to this unit. The speed number is determined by load.'
+ # FIXME: Temporary
+ next if message.include?('Heating COP Function of Temperature Curve Name') && message.include?('output is not equal to 1.0 (+ or - 10%) at rated conditions.')
+
# HPWHs
if hpxml.buildings.any? { |hpxml_bldg| hpxml_bldg.water_heating_systems.count { |wh| wh.water_heater_type == HPXML::WaterHeaterTypeHeatPump } > 0 }
next if message.include? 'Recovery Efficiency and Energy Factor could not be calculated during the test for standard ratings'
@@ -363,14 +366,15 @@ def _verify_outputs(rundir, hpxml_path, results, hpxml, unit_multiplier)
if hpxml.buildings.any? { |hpxml_bldg| hpxml_bldg.water_heating_systems.count { |wh| wh.water_heater_type == HPXML::WaterHeaterTypeHeatPump && wh.location == HPXML::LocationOtherExterior } > 0 }
next if message.include? 'Water heater tank set point temperature is greater than or equal to the cut-in temperature of the heat pump water heater.'
end
+ # WHs w/ mixing valves
+ if hpxml.buildings.any? { |hpxml_bldg| hpxml_bldg.water_heating_systems.count { |wh| wh.has_mixing_valve } > 0 }
+ next if message.include? 'Target water temperature is greater than the hot water temperature'
+ next if message.include? 'Target water temperature should be less than or equal to the hot water temperature'
+ end
# Stratified tank WHs
if hpxml.buildings.any? { |hpxml_bldg| hpxml_bldg.water_heating_systems.count { |wh| wh.tank_model_type == HPXML::WaterHeaterTankModelTypeStratified } > 0 }
next if message.include? 'Recovery Efficiency and Energy Factor could not be calculated during the test for standard ratings'
end
- # HP defrost curves
- if hpxml.buildings.any? { |hpxml_bldg| hpxml_bldg.heat_pumps.count { |hp| [HPXML::HVACTypeHeatPumpAirToAir, HPXML::HVACTypeHeatPumpMiniSplit, HPXML::HVACTypeHeatPumpPTHP, HPXML::HVACTypeHeatPumpRoom].include? hp.heat_pump_type } > 0 }
- next if message.include?('GetDXCoils: Coil:Heating:DX') && message.include?('curve values') && message.include?('Defrost Energy Input Ratio Function of Temperature Curve')
- end
# variable system SHR adjustment
if hpxml.buildings.any? { |hpxml_bldg| (hpxml_bldg.heat_pumps + hpxml_bldg.cooling_systems).count { |hp| hp.compressor_type == HPXML::HVACCompressorTypeVariableSpeed } > 0 }
next if message.include?('CalcCBF: SHR adjusted to achieve valid outlet air properties and the simulation continues.')